Menu - 6 - Thermo-regulation settings
Section
Digit 1
Digit 2
Digit 3 and 4
Type of control
6
0
0: Heating setting can be
adjusted by the user
1: Variable heating setting
depending on the external
temperature
2: Variable heating setting
depending on the room
temperature (Clima Manager)*
3: Variable heating setting
depending on the external and
room temperatures (Clima
Manager)*
Compensation
6
1
If
or
00 to 20 in intervals of 1
Slope
6
2
If or
0.3
0.5
1.0
1.2
1.5
2.0
2.5
3.0
Parallel shift
6
3
If or
from - 20 to 20 in intervals of 1
Inactive
6
4
--
Inactive
6
5
0
Inactive
6
6
--
Inactive
6
7
--
Inactive
6
8
--
Inactive
6
9
--
* Available only with Clima Manager