background image

lp-772 Rev. 000 Rel. 000 Date 3.17.21

3

Part 1 - General Safety Information

This water heater is approved for indoor installations only and is 

not intended for use as a pool heater. Clearance to combustible 

materials: 0” top, bottom, sides, and back. Heater must have room 

for service: 24” front, 6” top, and 6” sides are minimum recommended 

service clearances. (A combustible door or removable panel is 

acceptable front clearance.) This water heater has been approved 

for closet installation and installation on combustible flooring. Do 

not install directly on carpeting. Install the water heater in a location 

where temperature and pressure relief valve discharge or a leak will 

not result in damage to the surrounding area. If such a location is 

not available, install an auxiliary catch pan.

DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN 

SUBMERGED IN WATER. 

Immediately call a qualified service 

technician. The water heater MUST BE replaced if it has been 

submerged. Operating a previously submerged water heater could 

result in property damage, severe personal injury, or death.

NOTE: 

Water heater damage due to flood or submersion is considered 

an Act of God, and IS NOT covered under product warranty.

High heat sources (sources generating heat 100

o

F / 37

o

C or greater, 

such as stove pipes, space heaters, etc.) may damage plastic 

components of the water heater as well as plastic vent pipe materials. 

Such damages ARE NOT covered by warranty. It is recommended to 

keep a minimum clearance of 8” from high heat sources. Observe heat 

source manufacturer instructions, as well as local, state, provincial, 

and national codes, laws, regulations and ordinances when installing 

this water heater and related components near high heat sources.

Table of Contents

Part 1 - General Safety Information 

3

A. When Servicing the Water Heating System 

3

B. Heater Water 

3

C. Freeze Protection 

3

D. Water Temperature Adjustment 

3

Part 2 - Prepare the Water Heater 

4

A. What’s in the Box 

4

B. Locating the Water Heater 

4

C. Water Chemistry Requirements 

5

Part 3 - Piping 

7

A. Plumbing 

7

B. Recirculation Lines 

7

C. Thermal Expansion 

7

D. Condensation 

7

E. Insulation Blankets 

7

F. Temperature and Pressure Relief Valve 

8

G. Scalding 

8

H. Filling the Heater 

9

I. Applications 

9

Part 4 - Wiring 

10

Part 5 - Installation Checklist 

11

Part 6 - Operation 

12

A. Combination Thermostat and High Limit Control (ECO)             12

B. Thermostat Adjustment and ECO Reset 

12

C. Heating Element Replacement Procedure 

12

D. Anode Rod 

13

Part 7 - Maintenance 

13

Part 8 - Troubleshooting 

15

Part 9 - Replacement Parts 

16

Six (6) Year Limited Warranty 

17

Customer Installation Record Form 

19

Do not use this water heater for anything other than its intended 

purpose (as described in this manual). Doing so could result in 

property damage and WILL VOID product warranty.

A. When Servicing the Water Heating System

NOTE:

 When inquiring about service or troubleshooting, reference the 

model and serial numbers from the water heater rating label.
To avoid severe burns, allow water heater and associated equipment 

to cool before servicing.

B. Heater Water

Do not use petroleum-based cleaning or sealing compounds in a water 

heating system. Gaskets and seals in the system may be damaged. This 

can result in substantial property damage.
Do not use “homemade cures” or “patent medicines”. Damage to the 

water heater, substantial property damage, and/or serious personal 

injury may result.

C. Freeze Protection

NOTE:

 Consider piping and installation when determining heater 

location. Failure of the water heater due to freeze related damage IS 

NOT covered by product warranty.

NEVER use any toxic chemical, including automotive, standard glycol 

antifreeze, or ethylene glycol made for hydronic (non-potable) 

systems. These chemicals can attack gaskets and seals in water 

systems, are poisonous if consumed, and can cause personal injury 

or death.

NOTE: 

Obey all local codes. Obtain all applicable permits before 

installing the water heater.

NOTE: 

Install all system components and piping in such a manner 

that does not reduce the performance of any fire rated assembly.

UNCRATING THE WATER HEATER

 - Any claims for damage or 

shortage in shipment must be filed immediately against the 

transportation company by the consignee.

Installer - 

Read all instructions in this manual before installing. 

Perform steps in the given order.

User -

 This manual is for use only by a qualified heating installer 

/ service technician. Have this water heater serviced / inspected 

annually by a qualified service technician.

FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE 

CAN RESULT IN SUBSTANTIAL PROPERTY DAMAGE, SEVERE 

PERSONAL INJURY, OR DEATH.

Be sure to disconnect electrical power before performing service. 

Failure to do so could result in electrical shock, property damage, 

serious personal injury, or death.

D. Water Temperature Adjustment

If the water heater is going to have a set temperature above 120

o

F, it is 

recommended to use an ASSE 1017 rated mixing valve to avoid severe 

burns or death from scalding temperatures.

Summary of Contents for ARI POU-06

Page 1: ...hical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 ariston com lp 772 Rev 000 Rel 000 Date 3 17 21 The surfaces of these products contacted by potable consumable water contain less than 0 25 lead by weight as required by the Safe Drinking Water Act Section 1417 Use and Care Manual California Proposition 65 Warning Th...

Page 2: ...ding details 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not operate this water heater if it has been damaged or dropped 6 This water heater should be serviced only by qualified service personnel Contact the water heater installer or a qualified service agency...

Page 3: ...Heating Element Replacement Procedure 12 D Anode Rod 13 Part 7 Maintenance 13 Part 8 Troubleshooting 15 Part 9 Replacement Parts 16 Six 6 Year Limited Warranty 17 Customer Installation Record Form 19 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could result in property damage and WILL VOID product warranty A When Servicing the Water...

Page 4: ...nd domestic water piping where it will not be exposed to freezing temperatures All piping should be insulated Additionally place the water heater so that the drain controls and inlets outlets are easily accessible NOTE To save on heating costs and improve energy efficiency keep the distance between the water heater and fixtures to a minimum to reduce heat loss from excess piping and keep friction ...

Page 5: ...r treatment is recommended and additional more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional Water pH between 6 5 and 8 5 pH levels below 6 5 can cause an increase in the rate of corrosion pH of 8 5 or higher can potentially cause lime scale build up Maint...

Page 6: ...3500 35 8 28 7 23 9 20 5 17 9 16 2 14 5 4000 41 0 32 8 27 3 23 4 20 5 18 5 16 4 4500 46 1 36 8 30 7 26 4 23 0 20 7 18 4 5000 51 2 41 0 34 1 29 3 25 6 23 1 20 5 5500 56 4 45 1 37 5 32 2 28 2 25 4 22 5 6000 61 4 49 2 41 0 35 1 30 7 27 3 24 6 Table 2 Electrical Characteristics Table 3 GPH Recovery Figure 2 Dimensional Drawing Table 4 Specifications and Dimensions Model ARI POU 06 120V 1500W ARI POU 1...

Page 7: ...he water heater Do not cover the operating or warning labels attached to the water heater or attempt to locate them on the exterior of the insulation blanket Do not apply insulation to the top of the water heater This could interfere with the safe operation of the electrical junction box Do not cover the jacket access panel to the thermostat and heating element or T P valve Inspect the insulation ...

Page 8: ...rate correctly immediately replace with a new properly rated relief valve Test T P valve at least once annually to ensure the waterway is clear If valve does not operate turn the heater off and call a plumber immediately Take care whenever operating relief valve to avoid scalding injury or property damage FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION...

Page 9: ...afest water temperature for your applications I Applications TOP OPTION INSTALLATION Figure 4 Piping Details NOTE Drawings are meant to demonstrate system piping concept Heat traps are optional but recommended PIPING NOTES The following notes are applicable to all of the piping applications demonstrated on this page 1 Minimum pipe size should match connection size Upsize pipe accordingly if greate...

Page 10: ... in size may be required D This water heater must be properly grounded A ground lug is provided within the electrical control box for connection of a properly sized ground E Close the cover door of the wiring connection box Part 4 Wiring All wiring must conform to local codes and or the latest edition of National Electrical Code ANSI NFPA 70 Refer to wiring diagrams in this manual for proper wirin...

Page 11: ...Sufficient room to service heater Relief Valve Yes No Temperature and Pressure Relief Valve properly installed and discharge line run to open drain Discharge line protected from freezing Wiring Yes No Power supply voltage agrees with water heater rat ing plate Branch circuit wire and fusing or circuit breaker of proper size Electrical connections tight and unit properly grounded Water Supply Yes N...

Page 12: ... of water before the power is turned on The heating element will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty A Combination Thermostat and High Limit Control ECO After water and electrical connections have been made and tank is filled with water turn on power to the heater The heater is now in operation Each water heater is ...

Page 13: ...intenance NOTE In addition to the routine maintenance detailed in this manual this water heater should be inspected annually by a qualified service technician to assure that all the equipment is operating safely and efficiently The owner should make necessary arrangements with a qualified heating contractor for periodic maintenance of the heater Installer must also inform the owner that lack of pr...

Page 14: ...O NOT replace the water heater until full inspections of all possible water sources are determined and necessary corrective steps have been taken NOTE To check the fitting threads insert a cotton swab between the jacket opening and fitting If the cotton is wet follow the drain ing instructions in the Maintenance section of this manual Then re move the fitting Put pipe dope or Teflon tape on the th...

Page 15: ...ough Hot Water Heater undersized Reduce rate of heater use Defective element Check amperage replace element if low Miswired or defective thermostat causing only one element to work Check wiring or replace thermostat Water Too Hot or Not Hot Enough Thermostat setting too high or low Change setting as required Thermostat out of calibration Replace thermostat Thermostat access panel not in place Insp...

Page 16: ...tomer service please have ready 1 The water heater model serial number and electrical specifications voltage and wattage as marked on the rating plate 2 The part description as noted above and number of parts desired DO NOT attempt to repair electrical wiring thermostats heating elements or other operating controls Refer such repairs to qualified ser vice personnel Failure to do so could result in...

Page 17: ...in accordance with federal state and local codes and in installations prone to vacuum related damages 3 Maintain the water heater in accordance with the maintenance procedure listed in the manufacturer s provided instructions Preventive maintenance can help avoid any unnecessary breakdown of the water heater and keep it running at optimum efficiency 4 Maintain all related system components in good...

Page 18: ...facturer shall be liable for and shall pay for all charges for labor or other expenses incurred in the removal repair or replacement of the appliance or any component part s claimed to be defective or any expense incurred to remedy any defect in the product Such charges include but are not necessarily limited to 1 All freight shipping handling and delivery costs of forwarding a new appliance or re...

Page 19: ...tallation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please only sign after the Qualified Installer Service Technician has fully reviewed the installation safety proper operation and maintenance of the system If the system has any problems please call the Quali...