Product rating 

274W Max at 240V 50Hz 

Electric approval AS/NZS 

60335.2.31:2013 

EMC AS/NZS 

CISPR14:2001 

Performance tested 

IEC61591

 

 
 

 

Trouble Shooting 

 

FAULT 

POSSIBLE CAUSE

 

SOLUTION 

 
Light on, but motor 

does not work 

Fan switch turned off 

Select a fan switch position 

Fan switch failed 

Contact Ariston Service  

Motor failed 

Contact Ariston Service  

Light and motor do 

not work 

House fuses blown 

Reset/ Replace fuses 

Power cord loose or 
disconnected 

Refit cord to power outlet. Switch 
power on 

Lights not working 

Broken/ Faulty globes 

Replace globes (Contact Ariston 

Service) 

Insufficient suction 

The distance between the 
range hood and the gas top is 

to far 

Refit the range hood to the correct 
distance 

The range hood 
inclines 

The fixing screw is not tight 
enough 

Tighten the hanging screw and make 
it horizontal 

 

NOTE: Any electrical repairs to this appliance must conform to your local, state and federal laws.   

Please contact the service centre if in any doubt before undertaking any of the above.  
Always disconnect the unit from the power source when opening the unit.

 