INSTALLATION
Fitting the Coaxial Flue
(Ø 60 / 100 Vertical)
Note: See table for maximum and minimum
fl
ue runs.
Contents:
1x Conical Adaptor (60/100mm)
1x Vertical Flue Kit (80/125mm)
The vertical
fl
ue kit is supplied with a specially designed
weather proof terminal
fi
tted, it can be used either with a
fl
at
roof or a pitched roof.
The Vertical
fl
ue kits useable lengths with the pitched roof
fl
ashings are indicated in Fig. 7.
Before proceeding to
fi
t the
fl
ue, ensure that the maximum
fl
ue
length has not been exceeded (See the tables) and that all
elbows and bends have been taken into consideration, for each
additional 90° elbow 1 metre must be subtracted from the total
fl
ue length, and for each 45° 0.5 metres must be subtracted from
the total
fl
ue length (the height of the vertical adaptor and a 45°
bend can be seen in Fig. 8).
Mark the position of the
fl
ue hole in the ceiling and/or roof (see
Fig. 7 for distance from wall to the centre of the
fl
ue).
Cut a 130mm diameter hole through the ceiling and/or roof and
fi
t the
fl
ashing plate to the roof.
DO NOT cut the vertical
fl
ue kit.
To connect the vertical
fl
ue kit directly to the boiler, place the
vertical starter kit (Part No. 3318079) (see Fig. 7) onto the exhaust
manifold and secure with the clamp,
fi
t the vertical adaptor onto
the vertical starter kit (note: there is no need to use a clamp to
secure this as it is a push
fi
t connection), the vertical
fl
ue kit must
then be inserted through the roof
fl
ashing, this will ensure that
the correct clearance above the roof is provided as the terminal
is a
fi
xed height.
Should extensions be required, they are available in 1 metre
(Part No. 3318077), 500mm (Part No. 3318078) and they must be
connected directly to the vertical starter kit before connecting
the adaptor to allow the vertical
fl
ue kit to be
fi
tted. In the event
that extension pieces need to be shortened, they must only be
cut at the male end and it must be ensured that the inner and
outer
fl
ue remain
fl
ush.
When utilising the vertical
fl
ue system, action must be taken
to ensure that the
fl
ue is supported adequately to prevent the
weight being transferred to the appliance
fl
ue connection by
using 1
fl
ue bracket per extension.
When the
fl
ue passes through a ceiling or wooden
fl
oor, there
must be an air gap of 25mm between any part of the
fl
ue
system and any combustible material. The use of a ceiling
plate will facilitate this. Also when the
fl
ue passes from one
room to another a
fi
re stop must be
fi
tted to prevent the passage
of smoke or
fi
re, irrespective of the structural material through
which the
fl
ue passes.
1
80
mm
Vert Adaptor
(supplied with flue kit)
Vertical Starter
Part No: 3318079
* This length will vary
according to the type
of flashing installed
Total length
of Vertical Kit
1355 mm
Useable length
of Vertical flue
690 mm*
Fig. 7
Fig. 8