![Ariston ALTEAS ONE Net 30 Installation And Servicing Instructions Download Page 38](http://html.mh-extra.com/html/ariston/alteas-one-net-30/alteas-one-net-30_installation-and-servicing-instructions_2970934038.webp)
38
/
TECHNICAL AREA
For accessing the
Technical Area
simultaneously press the ESC
and
buttons for 5 seconds; the
display will visualise the request
for entering the technical code.
Press the programming key
b
to select
234
and press the
button .
To move within the
Technical Area,
press the programming key
b
and press
button to access the selected window.
Press the programming key
b
to select a parameter and
press
button to access it.
To modify the value of a parameter,
press the programming key
b
and press
button to store the value.
Use the ESC
button to exit a parameter without storing the
modi
fi
cation and for returning to the normal viewing mode.
TECHNICAL AREA - reserved for quali
fi
ed technician
Accessing the
Technical Area
allows for setting/con
fi
guring the
device according to the speci
fi
c requirements of every installation
procedure.
It also provides important information relating to the e
ffi
cient
operation of the boiler.
The Technical Area comprises various display windows that allow
for directly accessing the parameters Intervening in each single
product installation/con
fi
guration phase.
The parameters relating to each single menu are listed in the
following pages.
The various parameters can be accessed and modi
fi
ed using the
button , the programming Keys
b
and the
ESC button
(
see picture below)
.
a.
ESC button (Back)
b.
Programming
keys
c.
OK
button
1,5 bar
CASCADE
AUTO
Central Heating
COMFORT
40
70
a
b
b
c
Insert technical code
222
Insert code
Save
Complete Menu
Configuration Wizard
Service
Faults
Technical area
Language, date and time
Example:
Modi
fi
cation of parameter
2.3.1 Max. Adjustable Central Heating Power
Proceed as follows:
1. Simultaneously press the ESC
and
buttons for 5
seconds; the display will visualise the request for entering the
technical code.
2.
Press the programming key
b
and select code
234
.
3. Press the
button; the
display will visualise the
available windows.
4.
Press the programming key
b
to select the
Complete Menu
.
5. Press the button to access;
the display will visualise the
available menus.
6.
Press the programming key
b
to select Menu
2 - Boiler
parameters
.
7. Press the
button. The
display will visualise the
available sub-menus.
8.
Press the programming key
b
to select
2.3 - Central
heating 1
.
9. Press the
button to
access.
The display will visualise the
parameters relative to sub-
menu 2.3.
10.
Press the programming key
b
to select parameter
2.3.1 - Max. C.H. Adjustable.
11. Press the button to access
the parameter.
The display will visualise the
value of the parameter (
50%
)
in addition to the minimum
and maximum values allowed.
12.
Press the programming key
b
to select the new value,
e.g.
46%
.
13. Press the
button to store
the modi
fi
cation.
(To exit the parameter without storing the modi
fi
cation, press
the ESC
button).
14. Press the ESC
button to return to the normal viewing
mode.
1 <Not Available>
2 Boiler Parameters
3 <Not Available>
4 Zone1 Parameters
Menu
0 Network
2.1 Free parameters
2.2 Settings
2.4 Central Heating-2
2 Boiler Parameters
2.0 General
2.3 Central Heating-1
2.3.1 Max CH Adjustable 50
2.3.2 <Not Available>
2.3.4 <Not Available>
2.3 Central Heating-1
2.3.0 Max CH Absolute 62
2.3.3 <Not Available>
50 %
Maximum value
100%
Minimum value
0%
2.3.1 Max CH Adjustable
46 %
100%
0%
2.3.1 Max CH Adjustable
Maximum value
Minimum value
Configuration Wizard
Service
Faults
Technical area
Language, date and time
Complete Menu