46
MAINTENANCE GUIDE
MAINTENANCE GUIDE: CLAS HE
3.3
DRAINING
DRAINING
Tools
Time
5 min
1
Turn the drain valve anti-clockwise to open and drain the water
from the boiler.
3.4
AUTOMATIC AIR VENT
AUTOMATIC AIR VENT
Tools
Time
5 min
1
Drain boiler (see 3.3). Remove the clip and lift the AAV from the
assembly
3.5
PRIMARY WATER PRESSURE SENSOR
PRIMARY WATER PRESSURE SENSOR
Tools
Time
5 min
1
Drain boiler (see 3.3). Remove the fixing clip, unplug the
electrical connector and lift the sensor from the assembly
Page. 10 of 24
Summary of Contents for 47-116-51
Page 63: ......