33
settings - adjustment - problem identification menus
Accessing the settings - adjustment - problem identification
menus
The boiler can be used to manage the heating and domestic hot
water production system in its entirety.
Navigation within the menus enables the boiler system +
connected peripheral units to be customised, optimising
operation for maximum comfort and maximum saving. It also
provides important information relating to the efficient operation
of the boiler.
The following menus are available:
The parameters relating to each individual menu are listed in the
following pages.
The various parameters can be accessed and modified using th
m
enu
/O
k
button and
programmation buttons
and
.
(see fig.
below).
To access the Menus, open the cover and proceed as follows:
1. Press the m
enu
/O
k
button; the first figure
0
00
will flash on the
display.
. Press the
buttons
or
to select a menu, for example:
“
2
00
3. Press the m
enu
/O
k
button; the second figures on the display will
flash, e.g. “
2
1
0
.
Caution!
The menus reserved for qualified technicians may only be
accessed after setting the access code.
4. Press the m
enu
/O
k
button;
222
will appear on the display unit.
5. Press the
buttons
or
to select code
234
6. Press the m
enu
/O
k
button to select the sub menu; the second
figures will flash, e.g. “
2
2
0
”.
7. Press the
buttons
or
to select a sub menu; for example:
“
2
3
0
8. Press the m
enu
/O
k
button to access the sub menu parameters; the
three figures will flash, for example: “
23
0
”.
9. Press the
buttons
or
to select a parameter; for example:
“
23
1
10. Press the m
enu
/O
k
button to access the parameter; the display will
indicate the value, e.g “
70
”.
Note:
The parameter value will be displayed for 0 seconds, then
will begin to flash in alternation with the parameter, e.g. “
70
>
231
.
11. Press the
buttons
or
to select the new value, e.g. “
75
”.
1. Press m
enu
/O
k
to save the change or press e
sC
to exit without
saving.
To exit, press the e
sC
button until the normal display screen is
restored.
For menus which do not require the access code, it is possible to pass
directly from the menu to the sub menu.
2 Boiler Parameter
1
Service code (accesso riservato tecnico qualificato)
General setting
3
C.H. Parameters - Part 1
4
C.H. Parameters - Part 1
5
Domestic Hot Water
9
Menù Reset to factory setting
3 Solar & Storage
3
0
General setting
3
1
Service code (accesso riservato tecnico qualificato)
3
Special setting
4 Zone 1 Parameters
4
0
Set-point Zone1
4
1
Service code (accesso riservato tecnico qualificato)
4
Zone 1 Setting
4
3
Diagnostics
4
4
Zone device mangement
5
Zone 2 Parameters
5
0
Set-point Zone
5
1
Service code (accesso riservato tecnico qualificato)
5
Zone Setting
5
3
Diagnostics
5
4
Zone device mangement
5
5
Multizone
7 Test & Utilities
8 Service Parameter
8
1
Service code (accesso riservato tecnico qualificato)
8
Boiler
8
3
Boiler Temperature
8
4
Solar & Storage
8
5
Service
8
6
Statistics
8
7
E@sy - NOT ACTIVE
8
8
Error History
p
rogrammatioN
button
Menu/Ok-
button
Summary of Contents for 47-116-51