3
.
S
T
AR
T
I
NG
A
ND OP
ERA
T
I
ON
3.1. Commissioning
3.1.1.
B
e
fo
re
co
nne
ct th
e
a
ppl
ian
c
e
to pow
er
s
o
ur
c
e,
fi ll th
e
t
an
k
u
p w
i
th
mains
w
a
t
er.
To do th
is,
t
urn
o
n
hot w
a
t
er
mi
x
er
t
a
p
an
d th
en
t
a
p of cold w
a
t
er
su
ppl
ie
d to th
e
w
a
t
er
h
ea
t
er.
3.1.2.
O
n
c
e
th
e
w
a
t
er
h
ea
t
er
is
f
u
ll
,
th
e
w
a
t
er
w
i
ll fl ow f
r
o
m
th
e
mi
x
er
t
a
p
.
C
h
e
ck th
e
fl
an
g
e
fo
r
l
ea
k
a
g
es.
Cen
t
er
i
t
an
d t
i
ght
en
th
e
nu
t
s
i
f
ne
c
essar
y
.
3.1.3.
T
urn
th
e
hot w
a
t
er
t
a
p o
n
th
e
mi
x
er
off
.
3.1.4.
C
o
nne
ct th
e
a
ppl
ian
c
e
to pow
er
s
o
ur
c
e.
3.2. Temperature control
3.2.1.
In
m
od
e
l
s
e
q
ui
pp
e
d w
i
th
e
xt
erna
l co
n
t
r
ol
,
w
a
t
er
t
em
p
era
t
ure
c
an
b
e
co
n
t
r
oll
e
d by
a
h
an
dl
e
co
nne
ct
e
d to th
e
th
erm
o
s
t
a
t
in
a
cco
r
d
an
c
e
w
i
th
mar
k
s.
3.2.2.
I
f
an
a
ppl
ian
c
e
m
od
e
l do
es
n
ot h
a
v
e
an
e
xt
erna
l co
n
t
r
ol
,
t
em
p
era
t
ure
c
an
b
e
se
t by t
urnin
g th
e
a
dj
us
t
in
g
s
c
re
w of th
e
th
erm
o
s
t
a
t
in
th
e
ran
g
e
mar
k
e
d by”+”
an
d ”
-
”
si
g
ns.
3.2.3.
To do
s
o
,
d
is
co
nne
ct th
e
w
a
t
er
h
ea
t
er
f
r
o
m
th
e
pow
er
su
pply
an
d
rem
ov
e
th
e
pl
as
t
i
c cov
er
of th
e
a
ppl
ian
c
e.
3.2.4.
I
t
is
re
co
mmen
d
e
d to
ins
t
a
ll th
e
co
n
t
r
oll
er
in
a
po
si
t
i
o
n
co
rres
po
n
d
in
g
a
pp
r
ox
ima
t
e
ly to 75% of th
e
ma
x
ima
l v
a
l
ue.
In
th
is
c
ase,
th
e
a
ppl
ian
c
e
is
op
era
t
e
d
in
e
co
n
o
m
y
m
od
e
si
g
ni
fi c
an
tly
re
d
u
c
in
g th
e
ra
t
e
of
s
c
a
l
e
fo
rma
t
i
o
n.
4
.
M
AI
NT
E
N
A
N
CE
A
ND
RE
P
AIR
W
O
R
K
S
Attention! Do not try to repair the appliance by yourself. All maintenance and repair works should be carried
out by a qualifi ed technician in conformity with the safety norms and with any provisions set forth in this
manual.
4.1. Water Drain
I
f th
ere
is
a
po
ssi
b
i
l
i
ty th
a
t th
e
am
b
ien
t t
em
p
era
t
ure
d
r
op
s
b
e
low
0
°
C
in
th
e
r
oo
m
wh
ere
th
e
a
ppl
ian
c
e
is
ins
t
a
ll
e
d
,
d
rain
w
a
t
er
f
r
o
m
th
e
w
a
t
er
h
ea
t
er.
4.1.1.
D
is
co
nne
ct th
e
a
ppl
ian
c
e
f
r
o
m
th
e
e
l
e
ct
ri
c
a
l
su
pply;
4.1.2.
M
a
k
e
sure
th
a
t th
e
w
a
t
er
in
th
e
a
ppl
ian
c
e
is
of
sa
f
e
t
em
p
era
t
ure
;
4.1.3.
T
urn
off th
e
t
a
p of cold w
a
t
er
su
pply to th
e
w
a
t
er
h
ea
t
er
;
4.1.4.
T
urn
o
n
th
e
hot w
a
t
er
t
a
p o
n
mi
x
er
fo
r
p
ressure
re
l
ie
f
insi
d
e
th
e
t
an
k;
4.1.5.
T
urn
o
n
th
e
T
-
co
nne
cto
r
s
top v
a
lv
e
ins
t
a
ll
e
d
a
t hot w
a
t
er
o
u
tl
e
t
(mar
k
e
d w
i
th
re
d
rin
g
)
fo
r
air
a
cc
ess
in
to th
e
t
an
k
.
I
f
i
t
is
a
b
sen
t
,
rem
ov
e
th
e
co
nne
ct
i
o
ns
a
t th
e
w
a
t
er
h
ea
t
er
o
u
tl
e
t;
4.1.6.
C
o
nne
ct d
rain
ho
se
d
ire
ct
e
d
in
to th
e
se
w
er
to th
e
T
-
co
nne
cto
r
s
top v
a
lv
e
ins
t
a
ll
e
d
a
t th
e
cold w
a
t
er
in
l
e
t of th
e
w
a
t
er
h
ea
t
er
(mar
k
e
d w
i
th th
e
bl
ue
rin
g
)
an
d op
en
i
t
.
I
f th
ere
is
n
o T
-
co
nne
cto
r,
co
nne
ct th
e
ho
se
to w
a
t
er
h
ea
t
er
in
l
e
t;
4.1.7.
A
ft
er
d
rainin
g
,
ma
k
e
sure
th
ere
is
n
o w
a
t
er
insi
d
e
th
e
w
a
t
er
h
ea
t
er.
Freezing of water inside the water heater leads to irreversible changes and defects.
It invalidates all warranty liability on the part of the manufacturer.
4.2. Replacing internal parts
D
is
co
nne
ct th
e
w
a
t
er
h
ea
t
er
f
r
o
m
th
e
e
l
e
ct
ri
c
i
ty
su
pply
.
Rem
ov
e
th
e
a
ppl
ian
c
e
cov
er.
To
re
pl
a
c
e
th
e
th
erm
o
s
t
a
t p
u
ll
i
t
s
t
rai
ght
o
u
t ot th
e
cl
us
t
er
an
d d
is
co
nne
ct f
r
o
m
pow
er
su
pply
.
P
ri
o
r
to wo
r
k
,
th
e
w
a
t
er
h
ea
t
er
mus
t fi
rs
t b
e
em
pt
ie
d
.
F
o
r
m
od
e
l
s
w
i
th
an
au
tocl
a
v
e
fl
an
g
e,
rem
ov
e
th
e
nu
t
(
D
in
Fi
g
.
3
),
rem
ov
e
th
e
fl
an
g
e
hold
er
(
S
in
Fi
g
.
3
)
an
d op
en
th
e
fl
an
g
e
(
F
in
Fi
g
.
3
)
by p
ressin
g
i
t
insi
d
e.
Rem
ov
e
th
e
fl
an
g
e
by t
urnin
g
i
t o
n
i
t
s
a
x
is.
F
o
r
m
od
e
l
s
w
i
th
a
fl
an
g
e
o
n
th
e
5 bolt
s,
rem
ov
e
5
nu
t
s
(
C
in
Fi
g
.
4
)
an
d
rem
ov
e
th
e
fl
an
g
e
(
F
in
Fi
g
.
4
).
Th
e
h
ea
t
in
g
e
l
emen
t
an
d
an
od
e
r
od
are
a
tt
a
ch
e
d to th
e
fl
an
g
e.
D
urin
g
reassem
bly
,
ma
k
e
sure
th
a
t th
e
h
ea
t
in
g
e
l
emen
t
,
fl
an
g
e
g
as
k
e
t
an
d th
e
th
erm
o
s
t
a
t
are
p
u
t b
a
ck
in
th
eir
o
ri
g
ina
l po
si
t
i
o
ns.
We
re
co
mmen
d
re
pl
a
c
in
g th
e
fl
an
g
e
g
as
k
e
t
e
v
er
y t
ime
wh
en
reassem
bl
in
g
.
Prior to any repair or maintenance procedure, disconnect the unit from power source.
Use original spare parts of the manufacturer only.
4.3. Periodical maintenance
4.3.1. Magnesium anode
Th
e
ma
g
nesium
an
od
e
r
od
is
an
in
t
e
g
ra
l p
ar
t of th
e
p
r
ot
e
ct
i
o
n
s
y
s
t
em
of w
a
t
er
t
an
k
a
g
ains
t co
rr
o
si
o
n.
I
t’
s
ne
c
essar
y to ch
e
ck th
e
co
n
d
i
t
i
o
n
of th
e
ma
g
nesium
an
od
e
r
od
A
NNU
ALL
Y
.
In
c
ase
of
se
v
ere
w
ear,
th
e
ma
g
nesium
an
od
e
r
od
mus
t b
e
re
pl
a
c
e
d
.
Th
e
w
arran
ty fo
r
w
a
t
er
t
an
k w
i
th th
e
wo
rn
ma
g
nesium
an
od
e
r
od
(resi
d
ua
l vol
ume
is
l
ess
th
an
3
0
%
)
is
n
ot
v
a
l
i
d
.
Th
e
ma
g
nesium
an
od
e
r
od
s
ho
u
ld b
e
re
pl
a
c
e
d
a
t l
eas
t o
n
c
e
in
2
4
m
o
n
th
s
(e
xc
e
pt fo
r
th
e
w
a
t
er
h
ea
t
er
w
i
th th
e
in
t
erna
l t
an
k
ma
d
e
of
s
t
ain
l
ess
s
t
ee
l
).
The magnesium anode rod is a consumable item that cannot be replaced under warranty.
4.3.2. Safety valve
Th
e
sa
f
e
ty v
a
lv
e
(
p
ressure
sa
f
e
ty d
e
v
i
c
e)
mus
t b
e
ins
p
e
ct
e
d
re
g
u
l
ar
ly to ch
e
ck th
a
t
i
t
is
n
ot block
e
d o
r
d
ama
g
e
d
.
Re
pl
a
c
e
th
e
v
a
lv
e
o
r
rem
ov
e
l
imes
c
a
l
e
d
e
po
si
t
s
i
f
ne
c
essar
y
.
I
f th
e
sa
f
e
ty v
a
lv
e
is
e
q
ui
pp
e
d
w
i
th
a
l
e
v
er,
re
g
u
l
ar
v
a
lv
e
co
rre
ct op
era
t
i
o
n
ch
e
ck p
r
oc
e
d
ure
c
an
b
e
p
er
fo
rme
d w
i
th
i
t
s
h
e
lp
.
Th
e
d
raina
g
e
p
i
p
e
of th
e
sa
f
e
ty v
a
lv
e
ma
y g
enera
t
e
w
a
t
er
d
r
opl
e
t
s.
I
t
is
n
ot
a
d
e
f
e
ct;
i
t
is
d
ue
to
re
l
ie
f
wo
r
k f
un
ct
i
o
n
of th
e
v
a
lv
e
-
p
ressure
re
l
ie
f th
a
t occ
urs
wh
en
w
a
t
er
is
h
ea
t
e
d
in
en
clo
se
d
s
p
a
c
e
of th
e
inner
t
an
k
.
2
9
Summary of Contents for 350
Page 35: ...D A B C D B C 35 ...