88 / GB
MENU
SUB-MENU
PARAMETER DESCRIPTION
RANGE
DEFAULT
17
9
8
Heating running hours (h/10)
only read
17
9
9
DHW running hours (h/10)
only read
17
10
HP Diagnostics - 1
17
10
0
Outside air temperature
only read (°C)
17
10
1
HP water flow temp
only read (°C)
17
10
2
HP water return temp
only read (°C)
17
10
3
HP Evaporator temp
only read (°C)
17
10
4
HP Suction temp
only read (°C)
17
10
5
HP Discharge temp
only read (°C)
17
10
6
HP condenser outlet temp
only read (°C)
17
10
7
TEO
only read (°C)
17
11
HP Diagnostics - 2
17
11
0
Heat Pump Mode
OFF
Stand by
Cooling
Heating
Booster Heating
Booster Cooling
Rating in Heat Mode
Rating in Cooling Mode
Freeze Protection
Defrost
High Temperature Protection
Timeguard
System Fail
Hard System Fail
Pump Down
Soft Fail Mode
only read
17
11
1
HP Error
See inverter error table
only read
17
11
2
Safety thermostat
ON - OFF
only read
17
11
3
Flowmeter
0 ÷ 1200 l/min
only read (l/min)
17
11
4
Flow Switch
Open - Closed
only read
17
11
5
Inverter shut off protection
only read
17
11
6
PEVAP - Evaporator Pressure P
only read
17
11
7
PCOND - Condenser Pressure P
only read
17
12
HP Diagnostics - 3
17
12
0
Inverter Capacity
0 ÷ 11 kW
only read (kW)
17
12
1
HP Actual Compressor frequency
0 ÷ 1100 Hz
only read (Hz)
17
12
2
HP Set Compressor Modulation
0 ÷ 100%
only read (%)
17
12
3
Electric Heater 1
only read
17
12
4
Main circulator status
ON - OFF
only read
17
12
5
Fan 1 speed real
0 ÷ 1000 rpm
only read (rpm)
17
12
6
Fan 2 speed real
0 ÷ 1000 rpm
only read (rpm)
17
12
7
Expansion valve
0 ÷ 500
only read
17
13
HP Diagnostics - 4
17
13
0
Compressor on/off
only read
17
13
1
Compressor preheating
only read
17
13
2
Current fan 1 status
only read
17
13
3
Currnet fan 2 status
only read
17
13
4
4way valve heat/cool
only read
17
13
5
Base Panel Heater Status
only read
17
13
6
Compressor phase current
only read (mA)
17
14
EM Diagnostics - 1 Input