96 / GB
MENU
SUB-MENU
PARAMETER DESCRIPTION
RANGE
DEFAULT
19
1
0
Connectivity Status
OFF
Initialization
Idle
Acess Point initializing
Acess Point mode on
Station Mode - Connecting
Station Mode - Connected
Station Mode - Provisioning
Station Mode - Server Connected
Wifi error
19
1
1
Signal Level
19
1
2
Active Status
Not provisioned
Provisioned - Not active
Active
19
1
3
Serial Number
19
1
4
SW Upgrade Status
Initialization
Waiting for Update
Updating Micro 1
Updating Micro 2
19
2
Reset Menu
19
2
0
Re-configuration
Resettare? OK=Sì, esc=No
20
BUFFER
20
0
Configuration
20
0
0
Buffer Activation
OFF - ON
OFF
20
0
1
Buffer Charge Mode
Partial Charge (1 sensor)
Full Charge (2 sensor)
Partial Charge (1 sensor)
20
0
2
Buffer hysteresis
0 ÷ 20°C
5°C
20
0
3
Buffer heating setpoint temperature
[20 ÷ 70°C]
40°C
20
0
4
Buffer cooling setpoint temperature
[5 ÷ 23°C]
18°C
20
0
5
SG Buffer setpoint
[20 ÷ 70°C]
40°C
20
0
6
Buffer OFFSET PV Integration Setpoint
[0 ÷ 20°C]
0°C
20
0
7
Buffer SP Type
Fixed
Variable
Fixed
20
1
Diagnostic
20
1
0
Buffer temperature sensor (Low)
Only read
20
1
1
Buffer temperature sensor (Mid)
Only read
20
1
2
Buffer temperature sensor (High)
Only read
20
1
3
Buffer Charge Request
OFF – ON
Only read
20
2
Statistics
20
2
0
Buffer charge hours Heating (x10)
Only read
20
2
1
Buffer charge hours Cooling (x10)
Only read