0
NETWORK
0
2
BUS network
0
2
0
Network presence
System interface
Energy Manager
Heat Pump
Room Sensor
Zone Manager
0
3
System interface
0
3
0
Zone number
No zone selected
Zone selected
0
0
3
1
Room temperature correction
- 3; +3
0
0
3
2
SW Version Interface
4
ZONE1 PARAMETERS
4
0
Setpoint
4
0
0
T Day
10 - 30 °C
19°C Heat - 24°C Cool
4
0
1
T Night
10 - 30 °C
13°C
4
0
2
T set Z1
par. 4.2.5 - 4.2.6
20°C (LT) - 40°C (HT)
4
0
3
Zone frost temperature
2 - 15 °C
5°C
4
1
Summer/Winter Changeover
4
1
0
S/W function activation Z1
OFF - ON
OFF
4
1
1
S/W temperature threshold
10 - 30 °C
20°C
4
1
2
S/W delay time
[0-600]
300 min
4
2
Z1 Settings
4
2
0
Zone 1 temperature range
Low Temp
High Temp
High Temp
4
2
1
Thermoregulation
Fix Flow T
Basic Thermoreg
Room T Only
Outdoor T Only
Room+Outdoor T
Basic Thermoreg
4
2
2
Slope
0,2 - 1 (LT); 1 - 3,5 (HT)
0,6 (LT) - 1,5 (HT)
4
2
3
Offset
-14 ÷ +14 (HT); -7 ÷ +7 (LT)
0°C
4
2
4
Room Influence Proportional
0 - 20°C
2°C (LT) - 10°C (HT)
4
2
5
Max T
20°C ÷ 45°C (LT); 20°C ÷ 70°C (HT)
45°C (LT) - 60°C (HT)
4
2
6
Min T
20°C ÷ 45°C (LT); 20°C ÷ 70°C (HT)
20°C (LT) - 20°C (HT)
4
2
9
Heat request mode
Standard
RT Time Programs Exclusion
Forcing Heat Demand
Standard
4
3
Z1 Diagnostics
4
3
0
Room T
only read
4
3
1
Room T setpoint
only read
4
3
2
Flow temperature
only read
4
3
3
Return temperature
only read
4
3
4
Heat Request Z1
OFF - ON
only read
4
3
5
Pump Status
OFF - ON
only read
4
4
Z1 Zone Module Settings
4
4
0
Zone pump modulation
Fixed
Modulating on DeltaT
Modulating on Pressure
Modulating on DeltaT
4
4
1
Target deltaT for pump modulation
4 ÷ 25°C
7°C (LT) - 20°C (HT)
4
4
2
Pump fixed speed
20 ÷ 100%
100%
4
5
Cooling
4
5
0
T Set Cool Z1
par. 4.5.6 - 4.5.7
7°C [FC] - 18°C [UFH]
4
5
1
Zone 1 Cooling Temp Range
Fan Coil
UFH
Fan Coil
4
5
2
Thermoregulation type
ON/OFF
Fix Flow T
Outdoor T Only
ON/OFF
4
5
3
Slope
[18;33] FC; [0-30] UFH
25 FC; 10 UFH