Installation
4. Installation
The plotter will be installed and adjusted by a service technician at an
assigned location.
Connecting the power supply
ARISTOMAT with 1.1 kW pump system:
230 V, 50/60 Hz, 16 A.
ARISTOMAT with 3 kW pump system: 3-phase fixed connection
with 400 V, 50 Hz, 16 A.
These works may be carried out by qualifield personnel only!
Connecting compressed air
ARISTOMAT with a pneumatic tool head need compressed air with the
following requirements:
Regulated pressure: 6 bar (87.08 psi) pulse free
Air flow:
mind. 30 l/min (2.47 cf/min) oil and water free
•
Connect the air supply line or the compressor to the maintenance unit
and set the pressure to 6 bar (87.psi)
Connecting the computer
The ARISTOMAT is connected to the serial port of the computer via the
delivered cable
.
Installing tool heads
The ARISTOMAT is prepared to use different tool heads (option of deliv-
ery). The instructions are described in further chapters of tool heads.