Chapter 4
Cabling the Switch
The following topics are covered in this section:
•
•
•
Connecting Serial and Management Cables
4.1
Grounding the Switch
After mounting the switch into the rack, connect the switch to the data center ground. Figure 4-1
displays the location of the grounding lug on the front, left mounting ear for the DCS-7020SR-32C2
Important:
Grounding wires and grounding lugs (M4 x 0.7) are not supplied. Wire size should meet local
and national installation requirements. Commercially available 6 AWG wire is recommended for
installations in the U.S.
À la terre et de mise à la terre fils cosses (M4 x 0.7) ne sont pas fournis. Calibre des fils doit
satisfaire des exigences de l’installation locale et nationale. Disponible dans le commerce 6 fils
AWG est recommandé pour les installations aux États-Unis.
Figure 10: Earth Grounding Pad Sockets for DCS-7020SR-32C2
1 Ground lug
6 ESD
2 Blue handle indicates forward airflow
7 Console (Serial) port
3 Ethernet management port
8 USB port
4 System status LED
9 Power supply 2 status LED
5 Fan status LED
10 Power supply 1 status LED
4.2
Connecting Power Cables
Important:
Installation of this equipment must comply with local and national electrical codes. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.
15