otherwise, automatic  halt can be brought about.  At this point,  re-start the 

fan only. 

 

16.  The  applicable  temperature  range  is  -20

  to  40

.  The  water  in  the 

tank  is  easy  to  deteriorate  and  give  off-flavor,  so  please  change  water 

regularly. 

17. Do not put the fan under the power plug directly. 

18. Do not use the fan around the bath, shower nozzle or swimming pool. 

19.  The  fan  is  qualified  to  be  maintained  at  the  specified  maintenance 

shops. 

 

 

VI.

 

Cleaning and Maintenance 

 

 

★★★

Kind  Reminder:

  Over  a  long  period  of  running,  the  wind 

capacity and dust removing effects of the filter screen and wet curtain 

are  inefficient  because  of  dust  block.  So  it  is  overwhelmingly 

recommended cleaning them regularly.       

1. Clean the air filter 

Cut  off  the  power  supply  and  unscrew  the  fan  with  a  manual 

screwdriver.  Then  the  filter  screen  can  be  dismounted.  Take  mild 

detergent and banister brush to clean the screen and wash it with clean 

water,  finally,  make  sure  that  the  filter  is  completely  dry  before 

operating the unit.   

2. Clean the wet curtain 

Firstly,  cut  off  the  power  supply,  and  then  get  the  air  filter  screen 

down in order to take out the wet curtain from back cover. Next, use 

mild detergent and banister brush to clean the wet curtain and wash it 

with clean water, finally, dry it. 

3. Clean the water tank 

Cut  off  the  power  supply;  take  the  air  filter  screen  down,  and  then 

take out the water tank. The following is to remove the dirt in the tank 

by using a towel with a few detergents,. After that,  wash and rinse it 

with clean water, wipe it with a piece of dry cloth, finally, dry it. 

4. Clean the outer cover 

Clean the outer cover with a mild detergent and a piece of soft cloth. 

★★★

Attention:

 

 

Cut off the  power  supply before  cleaning  the  fan due to  the  high 

voltage in it. 

 

No water in any part of the control panel.   

Wet curtain 

Air filter   

Summary of Contents for ARICOOL2H

Page 1: ...RICOOL2H Contents I Functions 2 II Main Technical Parameters 4 III Electrical Schematic Diagram 5 IV Product Diagram 6 V Security Rules 7 VI Cleaning and Maintenance 8 VII Usage of Ice packs 10 VIII Troubleshooting and Maintenance 11 ...

Page 2: ...f the fan is devoid of water the button is void Heating While press the HEAT button it turns to be low heating function if second press is made it will be high heating function Timing in the working state if the button is pressed timer can be activated and if pressed repeatedly can be adjusted as follows 1hour 2hours 12 hours Natural wind in the working state the natural wind can be set by pressin...

Page 3: ...L2H VOLTAGE 220 240V FREQUENCY 50Hz POWER 120W 2000W CAPACITY 10L WIND SPEED 9 5 m s EVAPORATION CAPACITY 1 2 L h ENERGY EFFICIENCY 12 W W NOISE 65 dB TYPE Air cooler Display panel Temperature sensor Water level sensor Power panel swing motor Ionizer Pump Capacitor PTC heater ...

Page 4: ...s inside 9 The fan is applicable indoors while outdoor use is forbidden 10 When the water tank is full of water do not incline or collide the fan when putting or moving it If you intend to move the fan push it slowly and gently from side please prevent the water from overflowing 11 It s not allowed to turn over the fan or the accidents arise In case the fan is turned over for careless causes and t...

Page 5: ...en can be dismounted Take mild detergent and banister brush to clean the screen and wash it with clean water finally make sure that the filter is completely dry before operating the unit 2 Clean the wet curtain Firstly cut off the power supply and then get the air filter screen down in order to take out the wet curtain from back cover Next use mild detergent and banister brush to clean the wet cur...

Page 6: ...lfunctions and Maintenance Malfunction Possible reasons Solutions No display of LED 1 out of power or poor contact 2 Damaged screen 3 Burned blown fuse 4 Error of circuit board 1 Power on to good contacts 2 Replace the screen 3 Replace blown fuses 4 Replace the circuit board Out of control 1 Power interference 2 Surrounding interference 3 Errors of procedure 1 Power off 2 Move the fan and keep a c...

Reviews: