- 17 -
PELLET POWER:
This Menu allows to set the system’s combustion in automatic or manual mode in Pellet modality.
If the manual mode is set, the user can choose the combustion power. This menu is visible only if P11 is
different from 1.
WOOD POWER:
This Menu allows to set the system’s combustion in automatic or manual mode in Wood modality.
If the manual mode is set, the user can choose the combustion power. It is visible only if A36=1 and P11
is different from 0.
COMBUSTION RECIPE:
Menu to select the combustion recipe in Pellet modality. The maximum value is the number of
recipes visible to the user (parameter P04). This value can be set in the Secret Menu Default Settings. If
P04=1 or P11=1 the Menu isn’t visible.
CALIBRATION:
Menu to change the Auger’s work time or speed. The system has 10 calibration’s steps (0 value is
set by the factory). The calibration’s effect is valid only in Run Mode and Modulation for the current
recipe. For each step the value is increased or decreased of a per cent value P15 set in the Default Settings
Menu. This menu is visible only if P11 is different from 1.
Feed screw will start to work continuously. After 6-7 minutes later, pellet feeding screw will
be filled with pellets. Wait to see for pellets coming out of flexible hose for an extra 2 minutes in
order to be sure that you fill the screw completely. After 2 minutes stop the screw.
Before first start up and every time pellet specifications is changed the fuel feeding quantity
must be calibrated. Whenever the heating pellets are changed (size or length of pellet, density, etc.)
the feeding rate of pellet screw will also change, which will affect combustion dramatically.
After filling the screw, empty the pot and then run the pellet feeding screw for 15 minutes.