7
Connect Vent System
Install transition on top of hood (if removed for shipping) with 2 -
3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
A
B
For vented installations only:
1.
Fit vent system over the exhaust outlet.
2.
Measure from the bottom of the air deflector to the bottom of
the hood outlet. Cut the ductwork at the measured dimension.
Dimension
to measure
Roof outlet
Wall
outlet
3.
Seal connection with clamps.
4.
Check that back draft dampers work properly.
Electrical Connection
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL
SHOCK.
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1⁄
2
” strain relief.
A
C
B
A. Terminal box
B. Knockout
C. Terminal box cover
4.
Run home power supply cable through strain relief, into
terminal box.
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. UL listed wire connectors
D. White wires
E. Black wires
F. Green (or bare) and yellow-
green ground wires
G. Terminal box
A
B
C
D
E
F
G
5.
Use UL listed wire connectors and connect black wires (C)
together.
6.
Use UL listed wire connectors and connect white wires (E)
together.
I
WARNING
ELECTRICAL SHOCK HAZARD.
I
WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND
WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN
DEATH OR ELECTRICAL SHOCK.
7.
Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
8.
Tighten strain relief screw.
9.
Install terminal box cover.
10.
Reconnect power.