OPERATOR MANUAL
21
Refrigerant Charge selection
. The operator can choose between:
-
MANUAL
selection. Set the amount of refrigerant to be charged into the a/c system (with
'UP'
key to increase or
‘DOWN’
key to decrease the quantity. The smallest increment of refrigerant
charge weight is 0.01 kg (if the units of weight are to lb the smallest increment of refrigerant
charge weight is 0.02lb). Holding the
'UP'
or
'DOWN'
keys for longer than two second will cause
the increments of weight change to increase or decrease rapidly.
-
FROM DATABASE
. Select the vehicle and model from unit database.
Important:
Once the refrigerant charge weight has been set, open both hand manifold
valves and press the
'START
' key.
A/C system must be OFF.
The unit will perform all tasks in one automatic cycle and will print reports at the end of each
single operation.