4.1.5 Overlaod Indicator
The PTQ overload indicator clearly warns by means of optical and acoustic signals when the
measured values reach and exceed the given limits.
Explanation of Parts
No. Designation
Function
1
Flashing lights
•
Optical warning
2
Status LED
•
Status indicator
3
On / Off
•
Turn on / off
4
Ball Magnet
•
Attachment / Alignment
5
Loudspeaker
•
Acoustic warning
6
Cable socket
•
Anschluss Ladekabel oder
Datenkabel
7
Antenna
•
Radio connection
Table 7
– Overload Indicator: Operation and Display Elements
Operation
CAUTION!
Do not look directly into the flashing lights when turning on the
device!
The overlaod indicator is switchen on or off by briefly holding the
on/off switch.
The flashing lights also indicate the measurements state.
Blue
flashing indicates the stand-by-mode, the device is not
receiving data.
Green
light means the overload indicator is connected but no
value is exceeding its respective limit.
Red
flashing accompanied by the sounding of the alarm tone
indicates that one more more values have reached or exceeded the given limits.
The limits are managed in the computer software or the app on the mobile device.
NOTE
Older systems do not display the overload indicator in the listing of connected devices. When
the overload indicator shows green light in the beginning of the measurement it is connected
correctly.
A red status LED indicates that the battery needs to be charged.
Mounting
Overload warning devices are attached to the tree using inclinometer mounts. They should be
positioned with good visual contact to the winch operator.