Argo LILIUM ART 11 Operating Instructions Manual Download Page 4

19 

V 02/22

 

 To disconnect the appliance, set the switch to OFF and remove 

the plug from the socket. Only pull on the plug. Do not pull the 
cord. 

 Do not bend, drag or twist the cord, or apply force to remove it. 

Do 

not operate the unit if its cable or plug are damaged; doing so 
can cause fires or electric shock

. If the power cord is damaged, 

it must be replaced by a service centre. 

 Do not place heavy objects on top of the appliance.  

 To prevent water spills, empty the water tank before moving the 

appliance.  

 Do not tilt the dehumidifier onto one side or turn it upside down, as 

the water which runs out could damage the appliance.  

 

Do not operate the unit on unstable or sloping surfaces: 
water leaks can cause it to malfunction or cause excessive 
vibration and running noise.  

 The dehumidifier must be positioned 

at least 50 cm

 away from the 

wall or other obstacles, so that the heat can dissipate correctly.  

 

Close all open windows to maximise dehumidification 
efficiency. 

 

Do not insert objects or sharp instruments into the air outlet 
grille.  

 

Do not cover the air intake and outlet grilles in any way. 

WARNING! 
In the event of an anomaly, switch the appliance off and 
unplug it immediately. Do not dismantle, repair or modify this 
product freely. In the event of a malfunction, contact the after-
sales service centre directly. 

  Do not immerse the power cord, plug or any other part of the 

appliance in water or other liquids.  

 Do not expose the dehumidifier to direct sunlight. 

 Keep the appliance well away from sources of heat which could 

cause plastic parts to become warped. 

Summary of Contents for LILIUM ART 11

Page 1: ...UCTIONS Read the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Page 2: ...n different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that doesn t have any continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not p...

Page 3: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure the plug is inserted fully Do not use multiple adapters Do not touch the plug with wet hands Make sure the plug is clean Children aged be...

Page 4: ...s water leaks can cause it to malfunction or cause excessive vibration and running noise The dehumidifier must be positioned at least 50 cm away from the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles i...

Page 5: ...ng so can cause leaks and malfunction In the event of interference with other electrical appliances place the two products at a minimum distance of 70cm DESCRIPTION OF PARTS 1 Control panel 8 Side panel 2 Colored LED with humidity sensor 9 Air inlet and air filter 3 Front panel 10 Water tank 4 Casters 11 Water outlet 5 Side panel 12 Air outlet 6 Handle 13 Power cord 7 Rear panel FRONT VIEW REAR VI...

Page 6: ...t is in operation If you wish to make continuous draining of condensate follow the instructions in the dedicated paragraph OPERATING PRECAUTIONS The dehumidifier starts only if the humidity level in the room is higher than 3 the set one The dehumidifier will continue to operate until the set humidity level is reached except for any interruptions due to filling the tank When the water tank is full ...

Page 7: ...ich is inside the tank is correctly positioned Make sure not to damage the float and the locking rivet which are inside the tank otherwise the unit will not automatically stop working when the water tank is full and the water could leak out and risk wetting the tank floor and damage the appliance N B Do not use the drainage pipe when you want to collect the condensate in the tank otherwise the wat...

Page 8: ...lay then set the desired humidity level During operation the Power symbol on the display remains always on and the display shows the humidity level detected in the room during operation of the dehumidifier By pressing this button again the unit stops working and the ventilation stops 2 MODE BUTTON The unit works in the following circular sequence Auto Mode Continuous Mode Sleep Mode the correspond...

Page 9: ...howing the humidity level detected in the environment To deactivate the Timer 00 must appear on the display flashes 4 times and the Timer symbol on the display will turn off 5 SPEED BUTTON VENTILATION SPEED It is possible to adjust the ventilation speed only in Auto mode Press this button to adjust the speed from high to low the corresponding symbols will light up on the display according to the s...

Page 10: ...ly then insert it back into its housing Do not use hair dryer or fire to dry the filter Do not use sponges or brushes to clean the filter as they can damage it 2 2 Reposition the filter by inserting it as indicated by the arrow and replace the water tank Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator resulting in higher energy consumption CONSERV...

Page 11: ...d and the dehumidifier stops REGULATION EU N 517 2014 F GAS LILIUM ART 11 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 045 0 000135 Tons CO2 equiv Do not release R290 into the atmosphere LILIUM ART 13 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 050 0 000150 Tons CO2 equiv Do not release R290 into the atmospher...

Page 12: ...se any sources of ignition in such a manner that it may lead to the risk of fire or explosion AII possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed...

Page 13: ...ceptable for all refrigerant systems Electronic leak detectors may be used to detect refrigerant leaks but in the case of flammable refrigerants the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipm...

Page 14: ...ed refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed For appliances containing flammable refrigerants ensure that there are labels on the equipment stating the equipment contains flammable refrigerant R...

Reviews: