Argo EVAN PLUS Operating Instructions Manual Download Page 15

 

V 01/22

 

34

4. Transport.  

Preferably keep the air conditioner in the vertical position when 
transporting it.  
Should this not be possible, rest it on its right-hand side; when it 
reaches its destination, immediately put the appliance in the 
vertical position and wait at least 4 hours before using it in the 
cooling mode. 
 

 

5. For complete safety, regularly check the condition of the power cord; should it be damaged through use, 
contact the Service Centre to replace it. 

 

TIPS FOR MAXIMISING COMFORT AND MINIMISING CONSUMPTION

 

 
CHECK that: 

 

the unit's extraction and delivery grilles are always unobstructed;

 

 

the air filters are always clean: a dirty filter will decrease the passage of air and thus reduce the unit 
performance; 

 

the doors and windows are closed, to avoid infiltration of unconditioned air; 

 

the flexible hose is correctly positioned, without folds or sharp bends; 

 

the room temperature is above 18 ºC for the cooling mode, and above 10 ºC for dehumidification mode. 
 

 
 
 
 
 

REGULATION (EU) No. 517/2014 – F-GAS  

 

EVAN PLUS 
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3  - Kg. 0,21 = 
0,00063 Tons CO

2

 equiv. 

Do not release R290 into the atmosphere. 

 

 
 
 
 
 

 

INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT pursuant to art. 26 Legislative Decree 
14/03/14, no. 49 "IMPLEMENTATION OF EUROPEAN DIRECTIVE 2012/19 / EU ON WASTE FROM 
ELECTRICAL AND ELECTRONIC EQUIPMENT" 

At the end of its useful life, this appliance must not be disposed of with household waste. We recall the important 
role of the consumer in contributing to the reuse, recycling and other forms of recovery of such waste. 
The device must be delivered separately to appropriate municipal collection centers or free of charge at retailers, 
upon purchase of a new equivalent type of equipment. 
For products with an external dimension of less than 25 cm, this free waste collection service must be provided 
free of charge by large retailers (sales area of at least 400m2) even if no equivalent equipment is purchased. 
Disposing of an electrical and electronic device separately allows you to avoid possible negative effects on the 
environment and human health resulting from inappropriate disposal and allows you to recover and recycle the 
materials it is made of, with important savings in energy and resources. 
To emphasize the obligation to dispose of these equipment separately, the product bears the crossed out bin 
symbol. 

 

 
 
 

 
 

 
 

Summary of Contents for EVAN PLUS

Page 1: ...NS Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or...

Page 2: ...different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be danger...

Page 3: ...be made by children without supervision Ensure that the electricity system is able to deliver the operating current required by the air conditioner in addition to that normally absorbed by other appl...

Page 4: ...he remote control to OFF and remove the plug from the socket Pull on the plug only Do not pull the cord Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it...

Page 5: ...on a flat and stable surface so as to avoid water leaks The air conditioner is fitted with a system for protecting the compressor from overload This means that the compressor only starts 3 minutes af...

Page 6: ...held liable if safety and accident prevention rules are not observed DESCRIPTION OF THE APPLIANCE FRONT VIEW REAR VIEW 1 CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL 2 FLAP AIR INTAKE AN...

Page 7: ...he following space must be maintained to ensure the operating efficiency of the portable air conditioner The unit must be placed vertically for 2 hours before the first power on APPLIANCE START UP Ope...

Page 8: ...af towards it USE WITH WINDOW KIT 1 To make the hole in the glass it is advisable to take the porthole kit accessory to the glazier 2 Insert the window unit B into the window 3 Insert the round fittin...

Page 9: ...E HEAT The Heat LED on the control panel will turn on The temperature can be adjusted to between 16 C and 31 C In this mode each time the ON OFF button is pressed the unit switches off the appliance s...

Page 10: ...d blocking the operation of the device Cooling and Heating When the unit operates in the cooling and heating mode ensure that the rubber cap closing the drainage opening on the back of the appliance i...

Page 11: ...rical quantity is lacking and the battery must be replaced 12 Battery waste must be disposed of properly Note The image is a general remote control it contains almost all the function keys They may be...

Page 12: ...ime C Sleep on off D Speed setting E Display timer and temperature F Swing on off G Timer set H Signal transmission I Heating mode L Battery level 1 ON OFF BUTTON When turned on the unit emits an audi...

Page 13: ...g Unit Press TIMER Press Timer again to select a number of hours from 1 to 24 Press the TIMER button to confirm Resetting the timer If a TIMER has been set press TIMER to display the delay Press TIMER...

Page 14: ...ds talcum powder and brushes they may damage the surface or colour of the casing Remove any stains using warm water with a little neutral detergent Do not pour water onto the air conditioner to clean...

Page 15: ...0 21 0 00063 Tons CO2 equiv Do not release R290 into the atmosphere INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT pursuant to art 26 Legislative Decree 14 03 14 no 49 IMPLEMENTATION OF EUROPEAN...

Page 16: ...refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area No ignitio...

Page 17: ...ents are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall beat the correct rating Replace components only with parts specified by the...

Page 18: ...menced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for han...

Page 19: ...ered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially n...

Reviews: