4. VENTILATION MODE (FAN ONLY)

 

 

Press the MODE button until the Fan icon appears. 

 

In this mode, the fan speed can be adjusted. 

 

The temperature cannot be adjusted. 

 

 

HOW TO ELIMINATE CONDENSATE

 

 
This appliance automatically vaporizes the condensation in cooling. 
When the air conditioner operates in 

Cooling

, it is not necessary to have continuous condensate drainage; only in 

particular climatic conditions in which the air humidity is very high, it can happen that water is deposited inside the unit. 
In

 heating 

the condensate is not vaporized automatically, it will therefore be necessary to empty the tank periodically. 

Alternatively, drainage can be arranged from the lower hole on the back of the unit, the condensate drain will be 
intermittent. 

When the internal tank is full, the air conditioner will emit 8 beeps and the display will show the 

message "FL", signaling the filling and blocking the operation of the device. 

 

 
 

Cooling and Heating 

 
When the unit operates in the cooling and heating mode, ensure that the 
rubber cap closing the drainage opening on the back of the appliance is 
properly positioned. 
 
To empty the container, switch the air conditioner off and unplug the 
cord. Remove the cap from the rear drainage opening and place its end 
over a normal drain. Ensure that the tube is not twisted or bent. The tube 
must slope downwards. Re-close the drainage opening with the cap, 
insert it into the clamp and resume use of the air conditioner. 

 
Dehumidification 
 
WARNING! 

When using the air conditioner in dehumidification mode, we recommend always ensuring continuous drainage, in order 
to maximise dehumidification efficiency. 
Use the drainage outlet on the appliance. The water can be drained into a drain by simply connecting the supplied 
drainage tube.

 

 

 
 
 
 
 
 
 
 

 

 
 

 

 

 

1.  Remove the cap then remove the plug. 

2

.

Next, insert the drainage tube into the connection tube.  

 

Avoid bends in the drainage tube. When you want to stop continuous drainage, always replace the rubber plug and cap. 

 

Summary of Contents for EVAN PLUS

Page 1: ...NS Read the instructions carefully before operating the appliance or carrying out maintenance work Observe all the safety instructions failure to observe the instructions may lead to accidents and or...

Page 2: ...different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be danger...

Page 3: ...be made by children without supervision Ensure that the electricity system is able to deliver the operating current required by the air conditioner in addition to that normally absorbed by other appl...

Page 4: ...he remote control to OFF and remove the plug from the socket Pull on the plug only Do not pull the cord Do not use the appliance if the cord or plug are damaged If the power supply cord is damaged it...

Page 5: ...on a flat and stable surface so as to avoid water leaks The air conditioner is fitted with a system for protecting the compressor from overload This means that the compressor only starts 3 minutes af...

Page 6: ...held liable if safety and accident prevention rules are not observed DESCRIPTION OF THE APPLIANCE FRONT VIEW REAR VIEW 1 CONTROL PANEL AND FUNCTION BUTTONS WITHOUT REMOTE CONTROL 2 FLAP AIR INTAKE AN...

Page 7: ...he following space must be maintained to ensure the operating efficiency of the portable air conditioner The unit must be placed vertically for 2 hours before the first power on APPLIANCE START UP Ope...

Page 8: ...af towards it USE WITH WINDOW KIT 1 To make the hole in the glass it is advisable to take the porthole kit accessory to the glazier 2 Insert the window unit B into the window 3 Insert the round fittin...

Page 9: ...E HEAT The Heat LED on the control panel will turn on The temperature can be adjusted to between 16 C and 31 C In this mode each time the ON OFF button is pressed the unit switches off the appliance s...

Page 10: ...d blocking the operation of the device Cooling and Heating When the unit operates in the cooling and heating mode ensure that the rubber cap closing the drainage opening on the back of the appliance i...

Page 11: ...rical quantity is lacking and the battery must be replaced 12 Battery waste must be disposed of properly Note The image is a general remote control it contains almost all the function keys They may be...

Page 12: ...ime C Sleep on off D Speed setting E Display timer and temperature F Swing on off G Timer set H Signal transmission I Heating mode L Battery level 1 ON OFF BUTTON When turned on the unit emits an audi...

Page 13: ...g Unit Press TIMER Press Timer again to select a number of hours from 1 to 24 Press the TIMER button to confirm Resetting the timer If a TIMER has been set press TIMER to display the delay Press TIMER...

Page 14: ...ds talcum powder and brushes they may damage the surface or colour of the casing Remove any stains using warm water with a little neutral detergent Do not pour water onto the air conditioner to clean...

Page 15: ...0 21 0 00063 Tons CO2 equiv Do not release R290 into the atmosphere INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT pursuant to art 26 Legislative Decree 14 03 14 no 49 IMPLEMENTATION OF EUROPEAN...

Page 16: ...refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO2 fire extinguisher adjacent to the charging area No ignitio...

Page 17: ...ents are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall beat the correct rating Replace components only with parts specified by the...

Page 18: ...menced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for han...

Page 19: ...ered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially n...

Reviews: