7
EG
How to install Emix tank
Emix works only with an iSeries outdoor unit system; it is commonly connected to the proper EMX port but could be
connected also to a normal port like G30 that has an adapter from 3/8” to 1/4” for the liquid return flare. Anyway in
emergency conditions, you can use Emix tank as electrical water heater without the iSeries heat pump.
As first step you have to remove the bottom cover simply by your hand; it is not fixed by screw and you have only to
pickup it by the basement.
1.
Control panel
2.
Main switch
(selector switch)
3. Thermostat
(locked to 85 °C)
4.
Cold water inlet
5.
Hot water outlet
6.
Solar coil inlet
7.
Solar coil outlet
Detaching bottom sheet
Bottom front sheet is detached by pulling the sheet from
bottom end. When the sheet is partially open, pull the sheet
downwards.