Argo AW22AL Operating Instructions Manual Download Page 8

The above mentioned data make reference to the conditioner
operating when the sensor on the remote control unit is ON. (Refer
to temperature sensor selector). If the sensor on the indoor unit
is being used then actual operation will slightly differ from that
described in the above tables. (     ) Sign shown on the remote
control unit display).

ADJUSTING THE FAN SPEED

AUTOMATIC

Simply set the FAN SPEED selector to the              position
. A microcomputer automatically controls the fan speed when the
AUTO mode is selected. When the air conditioner starts operating,
the difference between the room temperature and the set
temperature is detected by the microcomputer which then
automatically switches the fan speed to the most suitable level.

WHEN DIFFERENCE BETWEEN

ROOM TEMPERATURE AND SET

FAN SPEED

TEMPERATURE IS

Cooling and

2 °C and over

High

dehumidifying modes:

Between 2 and 1 °C

Medium

Below 1 °C

Low

2 °C and over

High

Heating mode:

Below 2 °C

Medium

High speed

Med. speed

Low speed

MANUAL

If you want to manually adjust speed just set the FAN SPEED
selector as desired.

NOTE

1°C

1°C

1 hour

1 hour

TIME

Setting temperature

Room temperature

COOLING AND DEHUMIDIFYING

1

°

C

1

°

C

1 hour

1 hour.

TIME

Setting temperature

Room temperature

HEATING

SLEEP MODE

The SLEEP mode enables you to save energy.

1.

Set the MODE selector to cool, dry or heat.

2.

Press the SLEEP button.

3.

The            mark appears on the display. Press the SLEEP
button again to release the SLEEP function.

What does the SLEEP mode mean?

In this mode, the air conditioner will cool or heat the room to the
set temperature, and then the thermostat will make the unit pause.
After about 1 hour, the air conditioner will automatically reset the
set temperature as follows (also refer to graphs).

OPERATING MODE

SET TEMPERATURE CHANGE

Heating

Lowered by 1 °C

Cooling and Dehumidifying

Raised by 1 °C

When the room temperature reaches the new set value, the
thermostat will cause the unit to pause. After about 1 hour the
temperature will be raised by 1 °C in cooling, or lowered by 1 °C
in heating. This enables you to save energy without sacrificing
your comfort.

8

EG

DEHUMIDIFYING (DRY)

1.

Set the MODE selector switch to “DRY”

.

2.

Press the ON/OFF button and switch the air condioner ON.

3.

Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.). 

THE DISPLAY SHOWS THE SELECTED TEMPERATURE.

NOTE

Use DRY operation when you want to reduce the humidity in the
room.

Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically.

During DRY operation, the fan speed is automatically set to low
or stops to prevent overcooling.

Dry operation is not possible if the indoor temperature is 15 °C
or less.

NOTE

The air conditioner changes the operation mode (from cool to heat
or vice versa, if one of the following conditions occurs:
-

ZONE A:

changes if the difference between the room temperature

and the temperature set on the remote control unit is at least 3°C..

-

ZONE B: 

changes if the difference between the room temperature

and the temperature set on the remote control unit is at least 1°C,
one hour after the compressor stop.

ZONE C:

never changes if the difference between the room

temperature and the temperature set on the remote control unit is
no more than 1°C.

FAN ONLY

If you want to make air circulate without any temperature control,
follow these steps:

1.

Set the MODE selector switch to “FAN”

.

2.

Press the ON/OFF button and switch the air conditioner ON.

NOTE

In FAN Only mode the fan speed is adjusted automatically as in
cooling mode.

COOL / DRY / HEAT / FAN

Summary of Contents for AW22AL

Page 1: ...IONES DE USO MANUAL DE INSTRUÇÕES Ο Ο Η ΗΛ ΛΙ ΙΕ ΕΣ Σ Χ ΧΡ ΡΗ ΗΣ ΣΕ ΕΩ ΩΣ Σ Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimagerät Acondicionador de aire de consola partida sistema split Aparelho de ar condicionado Sistema Split ΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑ ΕΣ ΚΛΙΜΑΣΜΟΥ COOL DRY HEAT FAN Models ...

Page 2: ...CONFORMITY This product is marked as it satisfies Directives Low voltage no 73 23 EEC and 93 68 EEC Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or from non observance though partial of Manufacturer s installation and or operating instructions NOTE PRODUCT INFORMATION If you have problems or questions concerning your ...

Page 3: ...eiver receives signals transmitted from the remote control 6 Flexible drain tube removes condensate 7 Refrigerant tubes convey refrigerant between the indoor and outdoor unit 8 Operation selector without remote control Push the button to walk through the OFF COOL and HEAT operation modes EG 4 3 6 INDOOR UNIT OUTDOOR UNIT 7 1 2 INDOOR UNIT 5 OPERATION lamp 8 TIMER lamp STANDBY lamp FILTER lamp COOL...

Page 4: ...he air conditioner This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool the room too much if babies or invalids are present We recommend this air conditioner to be installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit Do not install this air conditioner wh...

Page 5: ...he power panel is turned ON and the the STANDBY lamp is light up When using the remote control unit always point the unit transmitter head directly at the air conditioner receiver HOW TO TURN ON THE AIR CONDITIONER Press the ON OFF button to turn the air conditioner on The indicator OPERATION will light up indicating the unit is in operation TRANSMITTER HEAD HOW TO INSTALL BATTERIES Remove the lid...

Page 6: ... status push again DISPLAY Information are displayed when the remote control unit is switched on TEMPERATURE SENSOR SELECTOR Push IFEEL button to activate the temperature control in the remote control unit This function provides a more confortable temperature control Press this button to select the desidered flap sweep function The flap moves up and down automatically Every time you push the butto...

Page 7: ...to set the desired temperature the temperature range is between 30 C max and 16 C min NOTE THE DISPLAY SHOWS THE SELECTED TEMPERATURE 4 Press the FAN SPEED button to select the fan speed 5 Press the FLAP buttons and adjust the air flow direction as desired see adjustment of air flow Make sure that the remote control is switched on Press the FLAP button to select automatic swing or one of the six m...

Page 8: ...rature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat will cause the unit to pause After about 1 hour the temperature will be raised by 1 C in cooling or lowered by 1 C in heating This enables you to save energy without sacrificing your comfort 8 ...

Page 9: ...ks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer B HOW TO SET THE ON TIME 1 Press the ON OFF button to stop the air conditioner 2 Press the TIMER button till the ON sign blinks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer C HOW TO SETAPROGRAM FOR DAILY ON OFF OPERATION OR ...

Page 10: ...nit will restart automatically after 3 minutes NOTE EG NOTES If you have lost the remote control unit or it has troubles follow the steps below 1 WHEN THE AIR CONDITIONER IS STOPPED If you want to turn on the air conditioner push the MODE button with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT THE REMOTE CONTROL UNIT The air conditioner will start in automatic fan speed and fla...

Page 11: ...ssible cause 1 Obstruction in front of condenser coil Remedy 1 Remove obstruction Trouble Poor cooling or heating performance Possible cause 1 Dirty or clogged air filter 2 Heat source or many people in room 3 Doors and or windows are open 4 Obstacle near air intake or air discharge port 5 Thermostat is set too high for cooling or too low for heating 6 Outdoor temperature is too low heat pump vers...

Page 12: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it Part No 4527348 01 ...