Argo AW22AL Operating Instructions Manual Download Page 11

11

TIPS FOR ENERGY SAVING

DO NOT:

Block the air intake and outlet of the unit. 
If they are obstructed, the unit will not work well, and may be
damaged.

Let direct sunlight into the room. Use sunshades, blind or
curtain.

DO:

Always try to keep the anti-mold filter clean. A clogged filter will
impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors
and any other openings closed.

TROUBLESHOOTING

WARNING

The use of portable telephones near the air-conditioner may cause
disturbance to its normal operation and must be avoided. In case
abnormal operation is noticed, to restore normal operation turn-
off electric supply for 60 seconds at least, by disconnecting the
main switch or the wall plug, then start again the air conditioner.

If your air conditioner does not work properly, first check the
following points before requesting service.
If it still does not work properly, contact your dealer or service
centre.

Trouble:

the air conditioner does not run at all.

Possible cause:

1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button on the remote control is OFF.
5. Batteries of the remote control unit have run down.

Remedy:

1. Restore power.
2. Contact service centre.
3. Consult your electrician or dealer.
4. Press the ON/OFF button on the remote control.
5. Replace batteries.

Trouble:

The air conditioner 

does not operate

and STANDBY

lamp flashes.

Possible cause:

1. Defective sensor.

Remedy:

1. Contact service centre.

Trouble:

TIMER lamp flashes and the air conditioner does not

operate.

Possible cause:

1. power failure during timer operation.

Remedy:

1. Press ON/OFF button on remote control.

Trouble:

Compressor runs but soon stops.

Possible cause:

1. Obstruction in front of condenser coil.

Remedy:

1. Remove obstruction.

Trouble:

Poor cooling or heating performance.

Possible cause:

1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high (for cooling) or too low (for heating).
6. Outdoor temperature is too low (heat pump version).
7. Defrosting system does not work (heat pump version).

Remedy:

1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower (or higher).
6. Try to use a back-up heater.
7. Consult your dealer.

Trouble:

Clicking sound is heard from the air conditioner.

Possible cause:

1. In heating or cooling operation, any plastic parts may expand

or shrink due to a sudden temperature change. In this event,
a clicking sound may occur.

Remedy:

1. This is normal, and the sound will disappear when an even

temperature is settled.

EG

AIR FILTER

The filter behind the air intake grille should be checked and cleaned
when the filter lamp lights up (see page 3).

HOW TO REMOVE THE FILTER

1.

Grasp both ends of the air intake grille and pull it towards you
and up.

2.

Push the filter up slightly, and then pull it down.

Air intake grille

Insert into the groove on the unit

Air filter

Air intake grille

FILTER CLEANING

HOW TO REPLACE THE FILTER

Use a vacuum cleaner to remove light dust. If there is sticky dust
on the filter, wash the filter in lukewarm, soap water, rinse it in
clean water, and dry it.

1.

With the «FRONT» mark facing you, slide the filter up

into the unit and then lower the handler   into the groove
on the unit.

2.

After installing the filter, press the locations marked by

the arrows (   ) and close the air intake grille.

3.

Press the 

RESET button

to turn off the filter lamp (see

page 3).

Air filter

Summary of Contents for AW22AL

Page 1: ...IONES DE USO MANUAL DE INSTRUÇÕES Ο Ο Η ΗΛ ΛΙ ΙΕ ΕΣ Σ Χ ΧΡ ΡΗ ΗΣ ΣΕ ΕΩ ΩΣ Σ Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimagerät Acondicionador de aire de consola partida sistema split Aparelho de ar condicionado Sistema Split ΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑ ΕΣ ΚΛΙΜΑΣΜΟΥ COOL DRY HEAT FAN Models ...

Page 2: ...CONFORMITY This product is marked as it satisfies Directives Low voltage no 73 23 EEC and 93 68 EEC Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or from non observance though partial of Manufacturer s installation and or operating instructions NOTE PRODUCT INFORMATION If you have problems or questions concerning your ...

Page 3: ...eiver receives signals transmitted from the remote control 6 Flexible drain tube removes condensate 7 Refrigerant tubes convey refrigerant between the indoor and outdoor unit 8 Operation selector without remote control Push the button to walk through the OFF COOL and HEAT operation modes EG 4 3 6 INDOOR UNIT OUTDOOR UNIT 7 1 2 INDOOR UNIT 5 OPERATION lamp 8 TIMER lamp STANDBY lamp FILTER lamp COOL...

Page 4: ...he air conditioner This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool the room too much if babies or invalids are present We recommend this air conditioner to be installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit Do not install this air conditioner wh...

Page 5: ...he power panel is turned ON and the the STANDBY lamp is light up When using the remote control unit always point the unit transmitter head directly at the air conditioner receiver HOW TO TURN ON THE AIR CONDITIONER Press the ON OFF button to turn the air conditioner on The indicator OPERATION will light up indicating the unit is in operation TRANSMITTER HEAD HOW TO INSTALL BATTERIES Remove the lid...

Page 6: ... status push again DISPLAY Information are displayed when the remote control unit is switched on TEMPERATURE SENSOR SELECTOR Push IFEEL button to activate the temperature control in the remote control unit This function provides a more confortable temperature control Press this button to select the desidered flap sweep function The flap moves up and down automatically Every time you push the butto...

Page 7: ...to set the desired temperature the temperature range is between 30 C max and 16 C min NOTE THE DISPLAY SHOWS THE SELECTED TEMPERATURE 4 Press the FAN SPEED button to select the fan speed 5 Press the FLAP buttons and adjust the air flow direction as desired see adjustment of air flow Make sure that the remote control is switched on Press the FLAP button to select automatic swing or one of the six m...

Page 8: ...rature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat will cause the unit to pause After about 1 hour the temperature will be raised by 1 C in cooling or lowered by 1 C in heating This enables you to save energy without sacrificing your comfort 8 ...

Page 9: ...ks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer B HOW TO SET THE ON TIME 1 Press the ON OFF button to stop the air conditioner 2 Press the TIMER button till the ON sign blinks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer C HOW TO SETAPROGRAM FOR DAILY ON OFF OPERATION OR ...

Page 10: ...nit will restart automatically after 3 minutes NOTE EG NOTES If you have lost the remote control unit or it has troubles follow the steps below 1 WHEN THE AIR CONDITIONER IS STOPPED If you want to turn on the air conditioner push the MODE button with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT THE REMOTE CONTROL UNIT The air conditioner will start in automatic fan speed and fla...

Page 11: ...ssible cause 1 Obstruction in front of condenser coil Remedy 1 Remove obstruction Trouble Poor cooling or heating performance Possible cause 1 Dirty or clogged air filter 2 Heat source or many people in room 3 Doors and or windows are open 4 Obstacle near air intake or air discharge port 5 Thermostat is set too high for cooling or too low for heating 6 Outdoor temperature is too low heat pump vers...

Page 12: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it Part No 4527348 01 ...

Reviews: