ELETRICAL REQUIREMENTS

INSTALLATION LOCATION

Before installation, check that the voltage of the electric supply
in your home or office is the same as the voltage shown on the
nameplate.

All wiring must conform to the local electrical codes. Consult
your dealer or a qualified electrician for details.

Each unit must be properly grounded with a ground (or earth)
wire or through the supply wiring.

Wiring must be done by a qualified electrician.

SAFETY INSTRUCTIONS

Read this booklet carefully before using this air conditioner.
If you still have any difficulties or problems, consult your
dealer for help.

This air conditioner is designed to give you comfortable
room conditions. Use this only for its intended purpose as
described in this Instruction Manual.

Never use or store gasoline or other flammable vapor or liquid
near the air conditioner. It is very dangerous.

Never install electrical equipment, which is not protected
with IPX1 protection (protection against vertical water drop),
under the unit.

The manufacturer assumes no responsabilities if the safety
regulations or local codes are not observed.

Never use the power main switch to start or stop the air
conditioner: always use the ON/OFF button on the remote
control unit or the selector switch on the unit.

Do not stick anything into the air outlet of the air conditioner.
This is dangerous because the fan is rotating at high speed.

Do not let children play with the air conditioner.

Do not cool the room too much if babies or invalids are
present.

We recommend this air conditioner to be installed properly
by qualified installation technicians in accordance with the
installation instructions provided with the unit.

Do not install this air conditioner where there are fumes
or flammable gases, or in an extremely humid space
such as a green house.

Do not install the air conditioner where excessively high
heat-generating objects are placed.

Do not install the air conditioner where the atmosphere
is extremely damp or humid (e.g. greenhouse or laundry)
it could be wetted by drops of water (i.e. in laundries).

Avoid

To protect the air conditioner from heavy corrosion, avoid installing
the outdoor unit where  salty sea water can splash directly onto
it or in sulphurous air near a spa.

The OFF position does not disconnect the power. Use the
main power switch to turn off power completely.

WARNING

CAUTION

OPERATION lamp:

This lamp lights up during operation.

It blinks once to announce that the remote control signal has been
received and stored. It blinks continuously during the protection
modes (defrosting, etc.).

STANDBY lamp:

This lamp lights up when the air conditioner is

connected to the power and ready to receive the remote control
command.

TIMER lamp: 

This lamp lights up when the system is being

controlled by the timer or sleep mode.

4

EG

WARNING

WARNING

CAUTION

Summary of Contents for AW22AL

Page 1: ...IONES DE USO MANUAL DE INSTRUÇÕES Ο Ο Η ΗΛ ΛΙ ΙΕ ΕΣ Σ Χ ΧΡ ΡΗ ΗΣ ΣΕ ΕΩ ΩΣ Σ Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimagerät Acondicionador de aire de consola partida sistema split Aparelho de ar condicionado Sistema Split ΙΑΙΡΟΥΜΕΝΕΣ ΜΟΝΑ ΕΣ ΚΛΙΜΑΣΜΟΥ COOL DRY HEAT FAN Models ...

Page 2: ...CONFORMITY This product is marked as it satisfies Directives Low voltage no 73 23 EEC and 93 68 EEC Electromagnetic Compatibility no 89 336 EEC 92 31 EEC and 93 68 EEC This declaration will become void in case of misusage and or from non observance though partial of Manufacturer s installation and or operating instructions NOTE PRODUCT INFORMATION If you have problems or questions concerning your ...

Page 3: ...eiver receives signals transmitted from the remote control 6 Flexible drain tube removes condensate 7 Refrigerant tubes convey refrigerant between the indoor and outdoor unit 8 Operation selector without remote control Push the button to walk through the OFF COOL and HEAT operation modes EG 4 3 6 INDOOR UNIT OUTDOOR UNIT 7 1 2 INDOOR UNIT 5 OPERATION lamp 8 TIMER lamp STANDBY lamp FILTER lamp COOL...

Page 4: ...he air conditioner This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool the room too much if babies or invalids are present We recommend this air conditioner to be installed properly by qualified installation technicians in accordance with the installation instructions provided with the unit Do not install this air conditioner wh...

Page 5: ...he power panel is turned ON and the the STANDBY lamp is light up When using the remote control unit always point the unit transmitter head directly at the air conditioner receiver HOW TO TURN ON THE AIR CONDITIONER Press the ON OFF button to turn the air conditioner on The indicator OPERATION will light up indicating the unit is in operation TRANSMITTER HEAD HOW TO INSTALL BATTERIES Remove the lid...

Page 6: ... status push again DISPLAY Information are displayed when the remote control unit is switched on TEMPERATURE SENSOR SELECTOR Push IFEEL button to activate the temperature control in the remote control unit This function provides a more confortable temperature control Press this button to select the desidered flap sweep function The flap moves up and down automatically Every time you push the butto...

Page 7: ...to set the desired temperature the temperature range is between 30 C max and 16 C min NOTE THE DISPLAY SHOWS THE SELECTED TEMPERATURE 4 Press the FAN SPEED button to select the fan speed 5 Press the FLAP buttons and adjust the air flow direction as desired see adjustment of air flow Make sure that the remote control is switched on Press the FLAP button to select automatic swing or one of the six m...

Page 8: ...rature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value the thermostat will cause the unit to pause After about 1 hour the temperature will be raised by 1 C in cooling or lowered by 1 C in heating This enables you to save energy without sacrificing your comfort 8 ...

Page 9: ...ks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer B HOW TO SET THE ON TIME 1 Press the ON OFF button to stop the air conditioner 2 Press the TIMER button till the ON sign blinks 3 Press the or HOUR button until the desired value is displayed 4 Press the SET button to activate the timer C HOW TO SETAPROGRAM FOR DAILY ON OFF OPERATION OR ...

Page 10: ...nit will restart automatically after 3 minutes NOTE EG NOTES If you have lost the remote control unit or it has troubles follow the steps below 1 WHEN THE AIR CONDITIONER IS STOPPED If you want to turn on the air conditioner push the MODE button with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT THE REMOTE CONTROL UNIT The air conditioner will start in automatic fan speed and fla...

Page 11: ...ssible cause 1 Obstruction in front of condenser coil Remedy 1 Remove obstruction Trouble Poor cooling or heating performance Possible cause 1 Dirty or clogged air filter 2 Heat source or many people in room 3 Doors and or windows are open 4 Obstacle near air intake or air discharge port 5 Thermostat is set too high for cooling or too low for heating 6 Outdoor temperature is too low heat pump vers...

Page 12: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it Part No 4527348 01 ...