Argo-Hytos SD1EX-A2 Operating Instructions Manual Download Page 19

Subject to change_SD1EX-A2(A3)_14088_1en_05/2022

Page 19

www.argo-hytos.com

A defective valve that is not caused by a malfunctioning solenoid coil must be removed and replaced with a new one.  

 

 

Repairs to a defective valve may only be carried out by the manufacturer.
When replacing the defective valve with a new one, proceed as follows: 

 › Ensure that no explosive atmosphere is present during the repair period. (see also 7.5).
 › Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
 › Relieve the hydraulic circuit including the accumulators by connecting it to the tank (see also 7.5).
 › Ensure that the hydraulic circuit is pressure-free (see also 7.5).
 › Switch off the electrical supply to the directional control valve solenoids (see also 7.5).
 › Ensure that the surface of the valve and solenoid coils is cooled to a low enough temperature to prevent skin burns (see also 7.5).
 › Clean the surface and area around the valve.
 › Remove the coil surface ground wire by loosening the M5x10 ground screw.
 › Disconnect the electrical supply cable to the coils (see 7.6.3).
 › Loosen the coil nut with a wrench (a = 36) and unscrew it.
 › Remove the sealing ring and spool from the valve control system.
 › Loosen the valve with a wrench (a = 24) and carefully unscrew it.
 › Allow the remaining working fluid from the valve to drain into the smaller container provided.
 › When installing the new replacement valve, follow the procedure in section 7.2 Product installation

Remove residual working fluid from the dismantled defective valveand package it to prevent mechanical damage and contamination of the area 
outside the package during transport. Send the packaged valve with a description of the manifestation of the defect to the manufacturer. A new 
valve is warranted by the manufacturer for 1 year. However, a claim may not be accepted by the manufacturer if the valve is mechanically damaged, 
the seal material is damaged by aggressive liquid, or the valve has been shown to have been used improperly and not in accordance with these 
instruction of use.

A suitably qualified user is authorised to replace the complete valve, the seals on the valve body, which are supplied as a kit. 
They can also replace a malfunctioning solenoid coil.

7.6 Repairs carried out by specialist

ENVIRONMENTAL PROTECTION

Spilled working fluid must be removed immediately, e.g. with suitable absorbents, contaminated parts of the perimeter cleaned, 
contaminated objects in the vicinity cleaned or disposed of. Kontaminated objects and residues of leaked working fluid must be 
disposed of in accordance with the applicable environmental regulations.

FIRST AID
Electric shock

 › Switch off the power supply immediately
 › Make sure the casualty is breathing.
 › Call emergency medical services
 › If the casualty is not breathing, initiate measures to restore basic life functions according to first aid abilities (CPR, artificial 

respiration) and equip the workplace (defibrillator) with life-saving equipment.

Contamination by hydraulic working fluid

If contamination of persons occurs, contaminated parts of clothing must be removed immediately and the skin thoroughly washed 
with soap or treated with a suitable cream. If the eyes are contaminated, flush them with clean water and seek medical attention. 
Seek medical attention also in case of accidental ingestion of working fluid or skin allergic reaction to splashes of working fluid.

A sealing ring in the recess behind the thread ensures the valve is sealed in the block and prevents working fluid from leaking out of the block.
Sealing rings on the steel valve housing separate the individual channels in the port from each other. If the ring is not fitted or is damaged, unwanted 
interconnection of the channels and unreliable control function of the valve will occur. In this case, the valve must be removed from the port and the 
sealing rings replaced with new ones.

 › Ensure that no explosive atmosphere is present during the repair (see also 7.5). 
 › Switch off the pressure source (pump) of the hydraulic circuit (see also 7.5).
 › Relieve the hydraulic circuit including the accumulators by connecting it to the tank (see also 7.5)
 › Ensure that the hydraulic circuit is de-pressurized (see also 7.5).
 › Switch off the electrical supply to the valve solenoids  (viz také 7.5).
 › Ensure that the surface of the valve and solenoid coils is cooled to a low enough temperature to prevent skin burns (see also 7.5)
 › Clean the surface and around valve.
 › Loosen the coil nut with a wrench (a = 36) and unscrew it.
 › Remove the sealing ring and spool from the valve control system.
 › Loosen the valve with a wrench (a = 24) and carefully unscrew it.
 › Allow the remaining working fluid from the valve to drain into the prepared smaller container. Dry the valve surface with a cleaning cloth.
 › Using a suitable tool, e.g. a small screwdriver, remove any sealing rings. Work carefully, do not damage the valve housing and threads.  

 

  Check the valve for damage and cleanliness.

 › Use a replacement seal kit. Thread the sealing rings into the recesses one by one in the correct place. Do not confuse the seals! Lubricate the new  

  seals with grease or working fluid.

 › Check the chamber in the block for damage and cleanliness.
 › When installing the new replacement valve into the block, follow section 7.2 Product installation.
 › After reassembling the solenoid to the valve control system, check that the solenoid cable in the grommet and the ground wire are properly  

 

  secured to ensure that they have not come loose during manipulation of the solenoid.

 › After the repair, verify that the new seals are tight and the valve is functioning properly.

7.6.1 Replacing a defective valve

7.6.2 Replacing the sealing rings on the valve housing

Summary of Contents for SD1EX-A2

Page 1: ...PILOTED DESIGNED FOR USE IN EXPLOSIVE ATMOSPHERES SD1EX A2 SD1EX A3 EN 1 2 2 3 1 SD1EX A2 SD1EX A3 1 2 The following is the authorised translation of original operating instruction SD1EX A2 A3 No 140...

Page 2: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 2 www argo hytos com Declaration of conformity...

Page 3: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 3 www argo hytos com...

Page 4: ...Subject to change_SD1EX A2 A3 _14088_1en_05 2022 Page 4 www argo hytos com...

Page 5: ...arameters 10 4 5 Working fluid 11 4 6 Valve characteristics 11 4 7 Legislation and standards 11 5 Product modifications 12 6 Target group of users 13 7 Operating instructons broken down into product l...

Page 6: ...IIA combustible fly particles IIIB non conductive dust and IIIC conductive dust 1 Use of product An overview of signal words and warning signs used in the text An overview of other symbols and abbrevi...

Page 7: ...C T100 C T85 C Db Areas of use 2 2 Cable grommet The cable grommet is a separately certified component with ATEX and IECEx certification I M2 Ex eb I Mb II 2G Ex eb IIC Gb II 2D Ex tb IIIC Db 2 3 Prot...

Page 8: ...d range see paragraph 1Product use in particular it is not intended for equipment category M1group l mines zone 0 group II gases and zone 20 group III dust Risk of explosion DANGER Surface temperature...

Page 9: ...aximum operating temperature The maximum operating temperature must not exceed the temperature range allowed in paragraph 4 4 Basic technical parameters or in the product catalogue Both the temperatur...

Page 10: ...ate PE The materials used are not found in the lists of prohibited and mandatory documented substances Directive 2015 863 EU RoHS and EU Regulation no 1907 2006 REACH 4 2 Materials used Parameter Unit...

Page 11: ...0 5 3 6 6 7 9 5 10 15 20 25 30 0 1450 2176 725 4351 5076 2901 3626 100 150 50 300 350 200 250 2 1 3 4 1 2 3 4 1 2 3 4 5 10 15 20 25 0 73 145 218 290 363 30 435 1 3 2 6 4 0 5 3 6 6 7 9 5 10 15 20 25 3...

Page 12: ...rew in chamber type 3 4 16 UNF A2 cavity A2 C 8 2 A3 cavity A3 C 8 3 High performance Valve connection see connection table Spool connection according to connection table DC voltage 01200 12 V DC 0 75...

Page 13: ...orrect Cut the packaging with scissors and carefully remove the valve from the packaging Unpack the valve in a clean place and prevent contamination of the valve The packaging is made of PE and can be...

Page 14: ...screw M3 with an inbus wrench a 2 5 mm to a torque of 1 2 0 2 Nm After mounting the valve it is necessary to ground the coil surface by connecting the ground wire to the terminal on the surface of the...

Page 15: ...Z 180 V for UN 110 V DC 1 2 1 2 Electrical wiring diagram of coils Coil type with DC electric power supply Nominal supply voltage Winding resistance at t 20 C Nominal current Limit current Bipolar dio...

Page 16: ...g the valve into the chamber in the block ensure that undamaged seals are fitted to the valve housing Also verify that the valve and chamber surfaces are not damaged or contaminated Before installing...

Page 17: ...cable diameter 30 2 Nm 22 1 0 4 lbf ft 5 1 Nm 3 7 0 7 lbf ft 3 4 6UNF 2A 46 1 81 43 1 69 40 1 57 82 3 23 128 5 04 16 0 63 58 2 28 46 1 81 36 1 42 15 82 0 62 14 22 0 56 6 8 0 24 31 0 85 3 35 1 2 3 24 6...

Page 18: ...lip soles In the event of a power failure to the solenoids or a coil failure the centering spring will return the valve spool to its base position Based on the results of the risk analysis the followi...

Page 19: ...vices If the casualty is not breathing initiate measures to restore basic life functions according to first aid abilities CPR artificial respiration and equip the workplace defibrillator with life sav...

Page 20: ...and a new fastening nut Replace the coil sealing rings with new ones They are supplied in a set with the coil and a new clamping nut Fit a new 22x1 5 sealing ring a new coil with attached cable a new...

Page 21: ...g code Valve hydraulic part seal kit 3 2 1 4 2 1 5 3 4 Valve type SD1EX A2 Position Set order number 20776700 1 O ring 17x1 8 NBR pcs 1 2 Dualseal 10 3x12 7x3 1 PU 1 Valve type SD1EX A3 Position Set o...

Page 22: ...8_1cz_05 2022 vydan v robcem D le it P ed pou it m v robku si pozorn p e t te n vod N vod k pou it uchovejte pro budouc pot ebu P i ztr t n vodu k pou it z sk te nov na webov ch st nk ch v robce ARGO...

Page 23: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 2 www argo hytos com Prohl en o shod...

Page 24: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 3 www argo hytos com...

Page 25: ...N vod k pou it _SD1EX A2 A3 _14088_1cz_05 2022 Strana 4 www argo hytos com...

Page 26: ...n kapalina 11 4 6 Charakteristiky ventilu 11 4 7 Pou it p edpisy a normy 11 5 Modifikace v robku 12 6 C lov skupina u ivatel 13 7 N vod k pou it len n podle f z ivota v robku 13 7 1 P eprava a skladov...

Page 27: ...til je certifikov n pro v echny skupiny prachu IIIA ho lav pol tav stice IIIB nevodiv prach a IIIC vodiv prach 1 Pou it v robku P ehled sign ln ch slov a v stra n ch zna ek pou it ch v textu P ehled d...

Page 28: ...T5 T6 Gb Ex eb mb IIC T4 T5 T6 Gb lI 2D Ex tb IIIC T135 C T100 C T85 C Db Ex tb IIIC T135 C T100 C T85 C Db Oblasti pou it 2 2 Pr chodka kabelu Pr chodka kabelu je samostatn certifikovanou sou st s ce...

Page 29: ...Ventil sm b t namontov n jen do odpov daj c komory T sn n nesm b t po kozen Ventil mus b t uta en stanoven m utahovac m momentem 30 2 Nm Jinak hroz nik pracovn kapaliny a uvoln n ventilu tlakem Podrob...

Page 30: ...C Ventil SD1EX A2 1 2 3 1 2 Ventil SD1EX A3 1 2 2S5 2S6 VAROV N Maxim ln provozn teplota Maxim ln provozn teplota kapaliny a okol nesm p ekro it rozsah teplot povolen v odstavci 4 4 Z kladn technick p...

Page 31: ...likon Pou it materi ly nejsou uvedeny v seznamech zak zan ch a povinn dokumentovan ch l tek Sm rnice 2015 863 EU RoHS a Na zen EU 1907 2006 REACH 4 2 Pou it materi ly Parametr Jednotka Hodnota Typ ven...

Page 32: ...156 SUS 1 3 2 6 4 0 5 3 6 6 7 9 5 10 15 20 25 30 0 1450 2176 725 4351 5076 2901 3626 100 150 50 300 350 200 250 2 1 3 4 1 2 3 4 1 2 3 4 5 10 15 20 25 0 73 145 218 290 363 30 435 1 3 2 6 4 0 5 3 6 6 7...

Page 33: ...16 UNF A2 komora A2 C 8 2 A3 komora A3 C 8 3 High performance Propojen ventilu viz tabulka propojen Nap jen c vky DC nap t 01200 12 V DC 0 75 A 02400 24 V DC 0 39 A 04800 48 V DC 0 19 A 11000 110 V D...

Page 34: ...typu ventilu na identifika n m t tku Obal rozst ihn te n kami a opatrn vyjm te ventil z obalu Ventil rozbalujte na ist m m st a zabra te kontaminaci ventilu Obal je vyroben z PE a m e b t lehce konta...

Page 35: ...maxim ln m pr ezu 2 mm2 upevn te pomoc roubov ku o ce 3 mm ke svorkovnici rouby dot hn te momentem 0 4 Nm 0 30 lbf ft Kabelov o ko zemn c ho vodi e navl kn te pod hlavu zemn c ho roubu um st n ho ved...

Page 36: ...C 12 16 1 0 750 0 65 36 8 9 EX18 046 10W 24V DC 24 61 8 0 390 0 34 36 9 3 EX18 046 10W 48V DC 48 252 4 0 190 0 16 75 9 1 EX18 046 10W 110V DC 110 1171 5 0 094 0 08 180 10 3 Typ c vky s AC elektrick m...

Page 37: ...ntilu do komory v bloku se ujist te e na pouzd e ventilu jsou nasazen nepo kozen t sn n Rovn prov te e povrch ventilu a komory nen po kozen a zne i t n P ed mont ventilu doporu ujeme lehce namazat t s...

Page 38: ...ou funkci ventilu Vinut elektromagnet se p i provozu zah v Pro nep ekro en maxim ln teploty vinut mus b t zaji t no inn vn j chlazen jednak nep ekro en m maxim ln teploty kapaliny a okol jednak dodr e...

Page 39: ...ov rukavice a pevnou obuv s protiskluzovou podr kou P i v padku elektrick ho nap jen elektromagnet nebo poru e c vky vr t pru ina ku elku ventilu do z kladn polohy Na z klad v sledk anal zy rizik byl...

Page 40: ...posti en d ch Zavolejte z chrannou l ka skou slu bu V p pad e posti en ned ch zahajte opat en k obnoven z kladn ch ivotn ch funkc podle vlastn ch schopnost mas srdce um l d ch n a vybaven pracovi t de...

Page 41: ...ek 22x1 5 novou c vku s p ipojen m kabelem nov t snic krou ek 21 89 x 2 62 a na roubujte novou up nac matici Matici dot hn te pomoc kl e momentem 5 1 Nm P ipojte k nov c vce vodi uzemn n Po ukon en v...

Page 42: ...v buchu objednac kl ARGO HYTOS Sada t sn n hydraulick sti ventilu 3 2 1 4 2 1 5 3 4 Typ ventilu SD1EX A2 Pozice Objednac slo sady 20776700 1 O krou ek 17x1 8 NBR ks 1 2 Dualseal 10 3x12 7x3 1 PU 1 Ty...

Reviews: