Subject to change_RPERX3-06_14095_1en_03/2022
Page 16
www.argo-hytos.com
7.5 Extraordinary and emergency situations
In the event of a power failure to the solenoids or a coil failure, the centering spring will return the valve spool to its base position.
Based on the results of the risk analysis, the following potential faults have been identified:
› External valve leakage due to seal damage associated with a working fluid leak.
› Loss of valve function, resulting in loss of control of the appliance.
› Mechanical damage to the electrical part of the valve, including the cable.
Defective valves must be replaced/repaired.
DANGER
Shutdown of electrical power, pressure source and circuit relief
In the event of an emergency, immediately shut off the electrical power supply to the control solenoids and
the pressure source (pump). Relieve all parts of the hydraulic circuit including the hydraulic accumulators by
connecting them to the tank. A malfunctioning valve may cause a dangerous operating situation due to loss
of control. A damaged electrical part can initiate an explosion.
DANGER
Prohibition of handling and repair in explosive atmospheres
A defective valve must not be repaired or dismantled when an explosive atmosphere is present.
There is a risk of initiating an explosion.
WARNING
Check pressure relief part of the circuit
Always ensure that the circuit is depressurised before intervening in the hydraulic circuit, for example before
removing a valve. Otherwise there is a risk of leakage of working fluid and contamination of persons.
WARNING
Surface temperature
Before starting disassembly, make sure that the surface of the valve and solenoid coils has cooled to a low
enough temperature to prevent skin burns.
ENVIRONMENTAL PROTECTION
Spilled working fluid must be removed immediately, e.g. with suitable absorbents, contaminated parts of the perimeter cleaned,
contaminated objects in the vicinity cleaned or disposed of.
Contaminated objects and residues of leaked working fluid must be disposed of in accordance with the applicable environmental
regulations.
FIRST AID
Electric shock
› Switch off the power supply immediately
› Make sure the casualty is breathing.
› Call emergency medical services
› If the casualty is not breathing, initiate measures to restore basic life functions according to first aid abilities (CPR, artificial
respiration) and equip the workplace (defibrillator) with life-saving equipment.
Contamination by hydraulic working fluid
If contamination of persons occurs, contaminated parts of clothing must be removed immediately and the skin thoroughly washed
with soap or treated with a suitable cream.
If the eyes are contaminated, flush them with clean water and seek medical attention. Seek medical attention also in case of
accidental ingestion of working fluid or skin allergic reaction to splashes of working fluid.
7.6 Repairs carried out by specialist
A suitably qualified user is authorised to replace the complete valve, the seals at the base of the valve body, which are supplied as a spare set.
They can also replace a malfunctioning solenoid coil.
Summary of Contents for RPERX3-06
Page 2: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 2 www argo hytos com ...
Page 3: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 3 www argo hytos com ...
Page 4: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 4 www argo hytos com ...
Page 21: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 2 www argo hytos com ...
Page 22: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 3 www argo hytos com ...
Page 23: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 4 www argo hytos com ...