Subject to change · FNA1HV 005_008_016_43622600 · 0421 · EN
Page 25
www.argo-hytos.com
12.3.4 Checking / changing the suction strainer FA 016.0303
The suction strainer should be checked - and if necessary changed - every three months or with anomalies (significantly lower
volume flow with a clean filter element, too loud operating noise).
When changing the suction strainer proceed as follows (see fig. 8):
1. Release the hose clamp (1) and pull the suction strainer (3) from the suction hose (2).
2. Clean the suction strainer (3) with cleaning solvent or diesel fuel or replace it if damaged (Order No. FA 016.0303) and dispose
of the used part in accordance with the environmental requirements, waste code: OIL FILTER 16 01 07.
3. Attach the suction strainer (3) to the suction hose (2) according to Fig. 8 and secure it with the hose clamp (1).
Fig. 8: Suction strainer FA 016.0303
Position
Designation
Order number
1
Hose clamp
DIN 03017
2
Suction strainer
FA 016.0303
Table 10: Spare parts suction strainer FA 016.0303