10.3.4 Installing the filter element
Fig. 7: Installing the filter element
10.4 Replacing the pump and the motor
Danger to life
Risk of electric shock.
›
Before uninstalling, disconnect the device from the power supply and pull the mains plug. Uninstalling may
only be carried out by qualified electricians.
›
Electrical work on the off-line filter units has strictly to be carried out by qualified electricians. Danger of
electrical shock.
Risk of injury
Risk of injury by incorrect handling
›
Uninstalling may only be carried out by instructed persons.
DANGER
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded
during operation.
›
Allow the filter unit to cool down before touching it.
6
5
4
3
2
1
10
9
8
7
Fig. 8: Replacing the motor and the pump
1. Carefully insert the cover (1) with the filter element (2) into the filter tube.
2. Screw in the cover manually until it stops. A gap between cover and filter pipe
may remain visible. (see Chapter 8.1 "Before commissioning" / Fig. 3)
CAUTION