7/8

USER'S MANUAL

Dimming/Switch Setting

Press 

DMX

 button into DMX status.

Press and hold the 

FNC

 button for 3 seconds.

The  default  setting  for  all  channels  (AL)  is 
dimming mode (=d).

Press 

FNC

 button to select channel.

Press  ▲  or  ▼  to  select  dimming  mode  (=d)  or 
switch mode (=S).

Warm­Up Setting (0 – 6%)

Press 

FNC

  button.  The  default  setting  for  all 

channels (A) is no pre­heat (00).

Press 

FNC

 button to select the channel, ie select 

channel 1
Press  ▲  or  ▼  to  adjust.  The  warm­up  level  can 
be adjusted from 1% to 6%.

Channel Output Status Preview

Enter to DMX status and press 

DMX

 button.

Press ▲ or ▼ to preview.

Manual Dimming

Move  the  sliders 

VR1

­

VR6

  to  dim  the  intensity  of 

the corresponding output channel.
When  a  DMX  signal  input  from  a  console  is  also 

present,  the  corresponding  output  channel  will 
take  the  higher  value  between  DMX  signal  and 
slider value.
When the dimmer pack is receiving a DMX frame, 
if  the  signal  is  lost  (or  the  cable  is  disconnected) 
the outputs will take the value set by the sliders.
Also,  if  the  projector  is  turned  on  and  it  is  not 
connected to a valid DMX signal, the light intensity 
is brought to the levels set by the sliders.

Display  the  Dimming  Value  of  DMX  Channel 
and Internal Temperature

Press 

L

  button  to  display  the  dimming  value  of 

DMX channel.
Press 

T

 button to display the internal temperature.

DMX­512 Status & DMX­512 Address

Press 

DMX

 button to DMX status.

The  LED  will  return  to  DMX  status  after  10 
minutes idle.

Protocol Control

When  the  protocol  control  turns  on,  it  only 
receives  the  DMX  signal  whose  break  width 
ranges from 88μs to 230μs.
Press 

FNC

  button  to  enable  or  disable  the 

protocol control.
Press  ▲  and  LED  displays  as  below,  protocol 
control is ON.

Press  ▼  and  LED  displays  as  below,  protocol 
control is OFF.

Summary of Contents for CO670L

Page 1: ...DMX Dimmer Pack 6ch User s Manual 10A x 6 channels dimmer pack with digital DMX analog 0 10V input control and pre heat function CO670L ...

Page 2: ...se trip hazard Do not attempt to dismantle and modify the unit Due to the high technological level of this unit any service maintenance should be performed by specialised operators Please contact your Arena Luci dealer for any operation Always ensure that the structure to which you are attaching the unit is secure and is able to support the weight of each unit Do not allow contact with water or an...

Page 3: ...therwise the unit will become over heat and will result in a malfunction The maximum output current of each channel is 10A this is a testing condition and must be held for 30 minutes maximum If the output current of each channel is less than 8A the unit can work for several hours in Theaters Stages and Studios If the output current of each channel is less than 8A the unit can work 24 7 without swi...

Page 4: ...nect the mains voltage from the system In the following connection diagrams you can find how to connect to the mains voltage for both Three Phase System and Single Phase System Respect the L N E polarity indicated on the terminals color brown L1 or L black L2 grey L3 blue N yellow green E It is essential that each unit is correctly earthed and that electrical installation conforms to all the stand...

Page 5: ... Canon XLR The unit also provides RJ11 connectors for DMX signal In carrying out the wiring of the connectors it is important that the signal wires do not make contact with each other and do not touch the casing of the plug The casing of the plug must not be in contact with other objects possible sources of disturbance The three terminals have the numbering referred to the poles of the XLR connect...

Page 6: ...annels Each dimmer pack must be given a digital start address number so that the correct unit responds to the correct control signals This digital start address is the channel number from which the unit starts to listen to the digital control information being sent out from the controller This digital encoding must be done on each unit The start address of the coding is assigned by setting the des...

Page 7: ...nnel will take the higher value between DMX signal and slider value When the dimmer pack is receiving a DMX frame if the signal is lost or the cable is disconnected the outputs will take the value set by the sliders Also if the projector is turned on and it is not connected to a valid DMX signal the light intensity is brought to the levels set by the sliders Display the Dimming Value of DMX Channe...

Page 8: ...int for the recycling of electrical and electronic equipment By ensuring this product is correctly disposed you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please c...

Reviews: