Installation Manual
Page | 12 [email protected]
+1.818.937.0700 877.CAMERA.8 www.arecontvision.com [email protected]
Mega
Video® Flex
Reset to Factory Default
1. Press and hold the reset button (#5) for 10 seconds and release the reset button. The camera
has been reset to the factory default
.
If the camera is not connected to DHCP server, the
camera will use a Link-local address.
2. Also can reset to factory default via camera web interface or AV IP Utility
NOTE: Additional information regarding the Arecont Vision
®
web interface is found separately in the
via the Arecont Vision website.
Changing the Lens
1. Remove the dome cover by loosening the tiny set screw on the ring surrounding the dome cover
with the supplied set screw driver.
2. Turn the metal ring of the bubble counter clockwise and remove.
3. Manually unscrew the lens counter clockwise, this may take several seconds.
4. Screw the replacement lens clockwise until you feel some resistance and hit a hard stop. Do not
over torque the screws.
5. Place the dome cover over the camera sensor and turn it clockwise until it hits a hard stop.
6. Tighten the set screw to lock the dome cover in place.
NOTE: Using MPM16.0 lens, you will need to rotate counter clockwise two (2) turns (720°) after Step 4
to account for the focus shift.
Removing the Bubble
1. To remove the dome cover, loosen the tiny set screw on the ring surrounding the dome cover
with the supplied set screw driver.
2. Turn the metal ring of the bubble counter clockwise to remove.
Attaching the Bubble
1. Place the dome cover over the camera sensor and turn it clockwise until it hits a hard stop.
2. Tighten the set screw to lock the dome cover in place with the supplied set screw driver.