Original User Manual 

 A

REBO

S Spa Pool Copenhagen/ Bora Bora 

 

14 

 
 

water back to 1°C above selected temperature. Once achieved, heater will stop to allow 
temperature to settle at pre-set value.  

5.4 Filtration System 

 

Press 

FILTER

, red light will appear, pump will start to work. Press 

FILTER

 again to stop pump, 

red light will go out.  

 

After approx. 168 hours, 

FC

 will appear on display screen (flashing) with a warning tone. Red 

light will be lit on 

FILTER

, pump 

will not

 be operational. Heating system will also not work 

and red light will be off.  

 

To make sure filtration system is off, press 

FILTER

FC

 on display screen will disappear as well 

as warning tone. Water temperature will be displayed, all functions will return to normal. 

FC

 

and warning tone remind user to replace filter. 

6. Maintenance and Repair 

Water level  

Water should be filled and mainta

ined between “Min” and “Max” fill lines as indicated on inner wall 

of your spa.  
 

Importance of water treatment 

You need to regularly monitor and appropriately treat the water in your spa.  
 

People with the following traits are at higher risk including:  

 

Diabetes, lung and heart disease 

 

Smokers and heavy drinkers 

 

Anyone with an impaired immune system 

 

People suffering from chronic respiratory or kidney disease.  
 

For more information contact your doctor. 

Water and legionnaires disease?  

Legionnaires’ disease can be c

ontracted by inhaling small droplets of water (called aerosols), which 

are suspended in the air and contain the bacteria. Certain conditions increase the risk of Legionella if:  

 

Water temperature in all or some parts of the system is between 20-45°C, which is suitable 
for growth of the bacteria.  

 

It is possible for breathable water droplets to be created and water is stored and/or re-
circulated.  

 

There are deposits that can support bacterial growth providing a source of nutrients for the 
organism e.g. rust, sludge, scale, organic matter and biofilms (from the body).  
 

Cleaning 

Detergent residues, dissolved solids from bathing suits and chemicals will gradually accumulate in the 
water. To clean your spa, use soap and water then rinse thoroughly. 

Please note:

 do not use hard brushes or abrasive cleaners.  

 

Repairing punctures  

If your spa is torn/punctured, use repair patches. Completely dry area to be repaired, apply strong 
adhesive to repair patch and then cover the damaged area. Smooth the surface to remove any air 
bubbles. Leave to dry for 12 hours before using the spa.  
 

Summary of Contents for AR-HE-SPA7DH

Page 1: ...ol Copenhagen Bora Bora 1 Spa Pool Copenhagen Bora Bora AR HE SPA7DP AR HE SPA7DH Product may differ from picture sample Please follow all security measures in this user s manual to ensure a secure us...

Page 2: ...3 Setting up 6 4 4 Tightening Inflation Valve 13 5 Operation 13 5 1 Setting the temperature 13 5 2 Inflate Air jets 13 5 3 Heater 13 5 4 Filtration System 14 6 Maintenance and Repair 14 7 Storage 15...

Page 3: ...1 Safety Instructions 1 1 Explanation of the symbols This product must not be disposed of with household waste By means of a CE marking it can be recognized that a product complies with the legal requ...

Page 4: ...blood pressure circulatory system problems or diabetes should consult a doctor before using spa People using medication should consult their doctor before using the spa Some medications may cause drow...

Page 5: ...M Seating capacity 7 Max water capacity 1120 L Max temperature 40 C Number of massage jets 130 140 Material of Top Lid Laminated PVC top cover with insulation coating Material of Spa pool inner wall...

Page 6: ...also put additional stress on the internal welds leading to a weld failure 4 During filling emptying or when in use water may spill out Install near to a drainage point capable of managing the volume...

Page 7: ...t Drainage Outlet 5 Assemble Hand Pump Pressure Gauge and Hose Insert and twist until locked 6 Locate Inflation Valve Remove valve cap Connect hose turning clockwise to lock Central button MUST be up...

Page 8: ...User Manual AREBOS Spa Pool Copenhagen Bora Bora 8 9 Once inflated turn anti clockwise to release inflation hose and replace valve cap 10 Unpack external unit screw 3x hoses onto external unit in ord...

Page 9: ...User Manual AREBOS Spa Pool Copenhagen Bora Bora 9 11 Align hoses with respective connectors and screw into place Plug in switch on 12 Inner features Water Circulation Outlet Filter Connector and Drai...

Page 10: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 10 13 Screw Filter Cartridge onto Filter Connector 14 Add Filter Protector Cover onto Filter Cartridge...

Page 11: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 11 15 Add water to level No higher than MAX level 16 Set temperature on control panel...

Page 12: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 12 17 Clip on Top Cover to retain the heat 18 Double lock clips with Safety Locking Keys...

Page 13: ...ss INFLATE AIR JETS to start air jets a red light will appear Press again and air jets will stop working red light will go out Air jets stop automatically after 20 minutes To reset wait for 10 minutes...

Page 14: ...art disease Smokers and heavy drinkers Anyone with an impaired immune system People suffering from chronic respiratory or kidney disease For more information contact your doctor Water and legionnaires...

Page 15: ...ined from the spa and pump system This is vital in extending the life of your spa We recommend the use of a wet dry vacuum to help blow out suck up water from pipes and pump lines Remove filter cartri...

Page 16: ...eset Heating system does not operate Temperature is set too low Dirty filter cartridge Improper water levels Heating element failure Set to a higher temperature 20 42 C than current water temperature...

Page 17: ...kaging in a bin for recyclable materials 9 2 Disposal of old equipment Old appliances must be disposed of in accordance with the guidelines and regulations of the local waste disposal authority Check...

Page 18: ...f conformity will lose its validity Tested acc to EU Standard EN 60335 2 60 2003 A1 2005 A2 2008 A11 2010 A12 2010 EN 60335 1 2012 A11 2014 A13 2017 A1 2019 A14 2019 A2 2019 EN 62233 2008 EN 55014 1 2...

Reviews: