Original User Manual
–
A
REBO
S Spa Pool Copenhagen/ Bora Bora
16
7.5 Winter storage
Drain all the water from the pool.
Remove the filter cartridge.
Clean and dry the SPA and attachments.
Expel all the air from the pool.
Loosely fold up the pool, avoiding sharp corners to prevent damage.
Store the pool in a dry, frost-free place.
The original packaging can be used for storage.
Caution !
Plastic can become brittle and fragile when it is exposed to sub-zero temperatures.
Freezing can severely damage the pool. Improper winter storage may invalidate the warranty.
The manufacturer cannot accept liability for damage to the pool and its components resulting from
the use of antifreeze agents.
8. Troubleshooting
Problems
Potential causes
Solutions
Air jet system is not
operating
Air pump too hot.
Something wrong with power box.
Air pump in cooling mode.
Unplug system. After air pump has
cooled, insert plug and press air jets
button to activate.
Wait for 10 Minutes and restart.
Call customer service if does not
reset.
Heating system does
not operate.
Temperature is set too low.
Dirty filter cartridge.
Improper water levels.
Heating element failure.
Set to a higher temperature (20
–
42°C) than current water
temperature.
Clean/replace filter cartridge.
Add water to specified levels.
Call customer service if does not
reset.
Filtering system
does not operate /
Rattling noise when
switching filter on
Dirty filter cartridge.
Something wrong with power box.
Clean/replace filter cartridge.
Call customer service if it does not
reset.
Ask a professional electrician to
check household electrical supply if
functioning correctly.
Spa leakage
Spa is torn or punctured
Use repair patch provided.
Water not clean
Insufficient filtering time.
Dirty filter cartridge.
Improper water maintenance.
Increase filtration time.
Clean/replace filter cartridge.
Refer to chemical manufacturer’s
instructions.
Display temperature
is higher than 42°C,
after stopping
heating function.
Residual water in the spa will
continue to be heated by residual
temperature.
Water inlet through filter system
may be blocked.
Unplug from mains and wait.
Temperature will start to reduce and
return to normal.
Clean the inlet.
Call customer service if does not
reset.