7.5 Winter storage 

Drain all the water from the pool. 
Remove the filter cartridge. 
Clean and dry the SPA and attachments. 
Expel all the air from the pool. 
Loosely fold up the pool, avoiding sharp corners to prevent damage. 
Store the pool in a dry, frost-free place. 
The original packaging can be used for storage. 

Caution ! 

Plastic can become brittle and fragile when it is exposed to sub-zero temperatures. 
Freezing can severely damage the pool. Improper winter storage may invalidate the warranty. 
The manufacturer cannot accept liability for damage to the pool and its components resulting from 
the use of antifreeze agents. 
 

8. Troubleshooting 

Problems 

Potential causes 

Solutions 

Air jet system is not 
operating 

Air pump too hot. 
Something wrong with power box.  
Air pump in cooling mode. 

Unplug system. After air pump has 
cooled, insert plug and press air jets 
button to activate. 
Wait for 10 Minutes and restart. 
Call customer service if does not 
reset. 

Heating system does 
not operate. 

Temperature is set too low.  
Dirty filter cartridge. 
Improper water levels. 
Heating element failure. 

Set to a higher temperature (20 

 

42°C) than current water 
temperature.  
Clean/replace filter cartridge.  
Add water to specified levels.  
Call customer service if does not 
reset.  

Filtering system 
does not operate / 
Rattling noise when 
switching filter on  

Dirty filter cartridge. 
Something wrong with power box. 

Clean/replace filter cartridge.  
Call customer service if it does not 
reset.  
Ask a professional electrician to 
check household electrical supply if 
functioning correctly.  

Spa leakage  

Spa is torn or punctured 

Use repair patch provided. 

Water not clean 

Insufficient filtering time.  
Dirty filter cartridge. 
Improper water maintenance.  

Increase filtration time.  
Clean/replace filter cartridge. 

Refer to chemical manufacturer’s 

instructions. 

Display temperature 
is higher than 42°C, 
after stopping 
heating function.  

Residual water in the spa will 
continue to be heated by residual 
temperature. 
Water inlet through filter system 
may be blocked. 

Unplug from mains and wait. 
Temperature will start to reduce and 
return to normal.  
Clean the inlet.  
Call customer service if does not 
reset.  

 

Summary of Contents for AR-HE-SPA7DH

Page 1: ...ol Copenhagen Bora Bora 1 Spa Pool Copenhagen Bora Bora AR HE SPA7DP AR HE SPA7DH Product may differ from picture sample Please follow all security measures in this user s manual to ensure a secure us...

Page 2: ...3 Setting up 6 4 4 Tightening Inflation Valve 13 5 Operation 13 5 1 Setting the temperature 13 5 2 Inflate Air jets 13 5 3 Heater 13 5 4 Filtration System 14 6 Maintenance and Repair 14 7 Storage 15...

Page 3: ...1 Safety Instructions 1 1 Explanation of the symbols This product must not be disposed of with household waste By means of a CE marking it can be recognized that a product complies with the legal requ...

Page 4: ...blood pressure circulatory system problems or diabetes should consult a doctor before using spa People using medication should consult their doctor before using the spa Some medications may cause drow...

Page 5: ...M Seating capacity 7 Max water capacity 1120 L Max temperature 40 C Number of massage jets 130 140 Material of Top Lid Laminated PVC top cover with insulation coating Material of Spa pool inner wall...

Page 6: ...also put additional stress on the internal welds leading to a weld failure 4 During filling emptying or when in use water may spill out Install near to a drainage point capable of managing the volume...

Page 7: ...t Drainage Outlet 5 Assemble Hand Pump Pressure Gauge and Hose Insert and twist until locked 6 Locate Inflation Valve Remove valve cap Connect hose turning clockwise to lock Central button MUST be up...

Page 8: ...User Manual AREBOS Spa Pool Copenhagen Bora Bora 8 9 Once inflated turn anti clockwise to release inflation hose and replace valve cap 10 Unpack external unit screw 3x hoses onto external unit in ord...

Page 9: ...User Manual AREBOS Spa Pool Copenhagen Bora Bora 9 11 Align hoses with respective connectors and screw into place Plug in switch on 12 Inner features Water Circulation Outlet Filter Connector and Drai...

Page 10: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 10 13 Screw Filter Cartridge onto Filter Connector 14 Add Filter Protector Cover onto Filter Cartridge...

Page 11: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 11 15 Add water to level No higher than MAX level 16 Set temperature on control panel...

Page 12: ...Original User Manual AREBOS Spa Pool Copenhagen Bora Bora 12 17 Clip on Top Cover to retain the heat 18 Double lock clips with Safety Locking Keys...

Page 13: ...ss INFLATE AIR JETS to start air jets a red light will appear Press again and air jets will stop working red light will go out Air jets stop automatically after 20 minutes To reset wait for 10 minutes...

Page 14: ...art disease Smokers and heavy drinkers Anyone with an impaired immune system People suffering from chronic respiratory or kidney disease For more information contact your doctor Water and legionnaires...

Page 15: ...ined from the spa and pump system This is vital in extending the life of your spa We recommend the use of a wet dry vacuum to help blow out suck up water from pipes and pump lines Remove filter cartri...

Page 16: ...eset Heating system does not operate Temperature is set too low Dirty filter cartridge Improper water levels Heating element failure Set to a higher temperature 20 42 C than current water temperature...

Page 17: ...kaging in a bin for recyclable materials 9 2 Disposal of old equipment Old appliances must be disposed of in accordance with the guidelines and regulations of the local waste disposal authority Check...

Page 18: ...f conformity will lose its validity Tested acc to EU Standard EN 60335 2 60 2003 A1 2005 A2 2008 A11 2010 A12 2010 EN 60335 1 2012 A11 2014 A13 2017 A1 2019 A14 2019 A2 2019 EN 62233 2008 EN 55014 1 2...

Reviews: