23
23
Mode button
When the device is switched on, press this button to change the operating
mode:
- ventilation (indicator Cool);
- minimum heating (indicator Low);
- maximum heating (indicator High).
Swing button
Press this button to activate or deactivate the automatic swing function
of the device. When the swing function is active, the corresponding
indicator Swing lights up.
Timer button
Press the TIMER button when the device is working to program
automatic switch-off at an interval of between 1 to 12 hours from when it
is programmed. Every time the button is pressed, the interval increases
by one hour.
A few seconds after selecting the timer, the display (2) will show the room
temperature again.
When the timer function is activated, the indicator
“Timer” lights up on
the control panel. To disable the timer function, press the timer button
repeatedly until the display shows “0 0”.
device switches on in summer ventilation mode “Cool”.
The display (2) will show the room temperature.
- When the device is switched on, press this button to turn it off.
Wait 30 seconds until the fan will stop; then switch off the appliance
by setting the main switch (6) to “0“.
Light button
Press this button to change the colour of the night light (9): off, blue,
purple, red. The night light can be turned on even when the device is
switched off, with the switch (6) on I.
24
Tem. Button
Press one of these buttons to set the desired room temperature
(automatic function); the set temperature will flash on the display (2).
Press button (+)/(Tem.) to increase the temperature or button “-“ to
decrease it: the set temperature will change from a minimum of 15°C to
a maximum of 40°C.
Once the desired temperature has been selected, the display (2) will
show the room temperature after a few seconds.
In automatic mode, the device will automatically regulate the heating
power based on the difference between the room temperature and the set
temperature. In this operating mode, the device will also switch between
the various power levels (ventilation, low power, high power) repeatedly.
The selected power level is always shown on the display. Once the set
temperature has been reached, ventilation will still remain active in order
to monitor the room temperature more effectively.
To disable this function, press the “Mode” button
and manually
select the desired function (ventilation only, low power or high power).
GB
Maintenance
This appliance does not require any special maintenance.
Disconnect the plug from the socket and let the appliance cool down well
before cleaning it.
In order to clean the appliance, use a soft or slight damp cloth.
Never use abrasives or chemical solvents.
Do not use very wet substances, liquids or cloths to prevent water from
entering into the apparatus and irreparably damaging it.
NEVER IMMERSE THE APPLIANCE INTO THE WATER.
Dust inside the appliance
Use a vacuum cleaner on the back grid.
Summary of Contents for AR4P19