background image

ARC-19516 

ArcVision Technology Corp. 

2

1.  Introduction 

 

The sixteen channels multiplexer has the following features: 

 

1.

 

Sixteen channels video input with loop-out and dynamic terminal resister settings. 

2.

 

Provides three video output ports (monitor out, call out and REC out). 

3.

 

Automatically detect NTSC/PAL video system. 

4.

 

Video input signals with AGC (Auto Gain Control) function. 

5.

 

Adopt E.A.L. (Erase Asynchronous Line) technique. 

6.

 

Support full-image and multi-windows (4, 6, 7, 8, 9, 10, 13 and 16 split) display format.   

7.

 

Multi-windows display refresh rate at 60 fields/sec for NTSC, 50 fields/sec for PAL. 

8.

 

Full duplex except 

Channel 16

 for recording and displaying. 

9.

 

Smart auto switch. Supports programmable channel sequence and automatic skip unconnected channels. 

10.

 

Supports freeze function for multi-windows and full-image display at normal and playback modes. 

11.

 

Supports 2X zoom function for full-image at normal and playback mode. 

12.

 

Supports sixteen-channel external alarm input ports and N.C./N.O. programmable property. 

13.

 

Record event lists (power-on, video loss, motion detection and alarm input) up to 256 records. 

14.

 

Supports general and time-lapse VCR recording mode for VCR and provides external-trigger, 2H, 12H, 
24H, real-time 24H, 48H, 72H, 120H, 168H, 240H, 480H, 720H, 960H for record time setting. 

15.

 

Supports priority record function. 

16.

 

Build-in RTC for date and time display. 

17.

 

Each camera supports camera title setting for up to seven characters. 

18.

 

Supports user-friendly hierarchy set-up menu. 

19.

 

Build-in color-bar generator for adjusting monitors. 

 

 
 
2.  Specification 

Refresh rate   
(Color Version) 

NTSC : 60 fields/sec, PAL : 50 fields/sec 

Resolution (HxV) 

NTSC : 860x525, PAL : 860x625 (CCIR-601 standard) 

Video input port 

BNCx16 cameras with loop out + BNCx1 REC play inputs 

Video output port 

BNCx1 Monitor out, BNCx1 Call Monitor our and BNCx1 REC Record out 

Video output signal 

1 Vp-p / 75

 CVBS out 

Video output format 

Full/Multi-windows (4, 6, 7, 8, 9, 10, 13 and 16 split) /Auto switch 

Title generator 

Up to 7 characters for each channel 

Timer generator 

Built-in RTC (real time clock) 

Dimension 

432(W) x 270(D) x 44(H) mm 

Power source 

DC 12V 

±

10

 

Power consumption 

18W(max), 1500mA@12V 
Recommend adapter: DC 12V/1.5A switching mode power adapter 

Summary of Contents for ARC-19516

Page 1: ...ARC 19516 Sixteen Channels Duplex Video Multiplexer User s Manual...

Page 2: ...ion Technology Corp 1 CONTENTS 2003 07 30 V1 1 040064 1 Introduction 2 2 Specification 2 3 Installation 3 4 Function Key Description 5 5 Operation Mode 6 6 Recording and Playback 7 7 Alarm Function 8...

Page 3: ...property 13 Record event lists power on video loss motion detection and alarm input up to 256 records 14 Supports general and time lapse VCR recording mode for VCR and provides external trigger 2H 12...

Page 4: ...M 8 External alarm input 8 7 ALARM 9 External alarm input 9 8 ALARM 11 External alarm input 11 9 GND Ground 10 ALARM 14 External alarm input 14 11 ALARM 16 External alarm input 16 12 RELAY OUT N C Rel...

Page 5: ...UT on the Mutiplexer and the other end to VIDEO IN on another Monitor The video format outputs from this port is programmable and displays full size image of any camera input It acts as a smart video...

Page 6: ...e press this button again when under normal mode condition 4 5 Press FREEZE key to freeze image s See next page operation mode for detail when under normal or playback multi window image condition 4 6...

Page 7: ...gins to flash 2 Press MULTI WIN key or camera channel selection keys to release the camera channel to multi window image or full image of the selected camera channel This mode supports 2X zoom functio...

Page 8: ...516 The acceptable trigger signal is a falling edge negative trigger b RECORD BY SETTING RECORDING TIME The multiplexer can calculate channel switching time by setting recording time at menu set up Th...

Page 9: ...urs the time in which it is put ON is also recorded It doesn t affect the buzzer and it is able to check whether or not it has once been turned off b When video loss occurs the relay and buzzer will b...

Page 10: ...bol represents level indication of the menu One symbol indicates that the menu is on level 1 two symbols indicates that the menu is on level 2 and so on c Item indicator Cursor Half tone area indicate...

Page 11: ...n to the menu on Figure 8 2 Note User must control the date in February by oneself 8 1 4 TIME DISPLAY Set to ON to display time and OFF to turn off the time display 8 1 5 TIME On the menu in Figure 8...

Page 12: ...t images 1 16 to display the full image of camera 1 16 to skip the sequence to next sequence 8 2 3 SEC dwell time The standby auto sequence time time unit second Press ENTER key to activate the edit p...

Page 13: ...splay the camera titles and OFF for no title display CAMERA SET UP CAMERA TITLE CAMERA TITLE DISPLAY CAMERA 1 2 3 SET UP CAMERA 4 5 6 SET UP CAMERA 7 8 9 SET UP CAMERA 10 11 12 SET UP CAMERA 13 14 15...

Page 14: ...rs 168H 240 hours 240H 480 hours 480H 720 hours 720H 960 hours 960H User must set the time to 2H when it is not a time lapse VCR 8 5 2 RECORDING TYPE Recording type can be set to FIELD field by field...

Page 15: ...4 ALARM OUTPUT Set on YES to turn the relay on if a valid alarm occurs Set on NO to keep relay to the current state 8 6 2 VIDEO LOSS CONFIG On the menu of Figure 8 9 select VIDEO LOSS CONFIG press EN...

Page 16: ...ct is small the value of sensitivity should increase until a M symbol appear on the right bottom corner of screen 8 6 3 2 4 BUZZER ENABLE Set YES to enable buzzer Once buzzer is enabled the buzzer wil...

Page 17: ...1 2 c The last field is the time of event occurring d User can use or key to turn the next page or the previous page e Press EXIT to escape the alarm list 8 6 9 CLEAR ALARM LIST On the menu of Figure...

Page 18: ...CTORY DEFAULT and press ENTER to enter the menu on Figure 8 16 to setting Figure 8 16 8 11 1 LOAD DEFAULT SETTING AND CLEAR ALARM LIST Load the parameters of factory default and erase alarm list 8 11...

Reviews: