8.4.3 CAMERA 1, 2, 3 SET UP
On the menu of Figure 8-4 select
“
CAMERA 1,2,3 SET UP
”
, and press <ENTER> to enter the menu on Figure 8-7 to set
brightness, contrast, chroma and sharpness for each camera.
8.5 VCR SET UP
On the main menu select
”
VCR SET UP
”
, and press <ENTER> to enter the menu on Figure 8-8.
Figure 8-8
8.5.1 RECORDING TIME
The multiplexer supports synchronous and asynchronous mode for VCR.
Synchronous mode:
To operate this mode, the recording time must be set to
“
SYNC
”
and the signals to
“
TRIGGER OUT
”
and
“
GND
”
, the VCR must
be connected to the multiplexer. Using synchronous mode is recommended, if your VCR supports this function.
Asynchronous mode:
The multiplexer supports 2 hours (2H), 12 hours (12H), 24 hours (24H), 24hours real motion (24RH), 48 hours (48H),
72 hours (72H), 120 hours (120H), 168 hours (168H), 240 hours (240H), 480 hours (480H), 720 hours (720H), 960 hours (960H).
User must set the time to
“
2H
”
, when it is not a time lapse VCR.
8.5.2 RECORDING TYPE
Recording type can be set to
“
FIELD
”
(field by field) or
“
FRAME
”
(frame by frame). It is only effective when the recording time is
set to
“
2H
”
.
8.6 ALARM PROCESSOR
On the main menu select
“
ALARM PROCESSOR
”
, and press <ENTER> to enter the menu on figure 8-9.
Figure 8-9
Figure 8-10
VCR SET UP ▊▊
-----------------------------
RECORDING TIME:24RH
RECORDING TYPE:FRAME
ALARM PROCESSOR ▊▊
-----------------------------
▊ALARM 1, 2, 3 CONFIGURE
▊ALARM 4, 5, 6 CONFIGURE
▊ALARM 7, 8, 9 CONFIGURE
▊ALARM 10,11,12 CONFIGURE
▊ALARM 13,14,15 CONFIGURE
▊ALARM 16 CONFIGURE
▊VIDEO LOSS CONFIGURE
▊MOTION SET UP
ALARM DURATION 01 MIN
ALARM LIST NO
ALARM FULL SCREEN NO
ANY KEY TO STOP YES
SHOW ALARM LIST
CLEAR ALARM LIST
ALARM 1,2,3 CONFIGURE ▊▊▊
-----------------------------
ALARM 1
SENSOR ENABLE:YES
SENSOR TYPE :N.O.
BUZZER ENABLE:YES
ALARM OUTPUT :YES
ALARM 2
SENSOR ENABLE:YES
SENSOR TYPE :N.O.
BUZZER ENABLE:YES
ALARM OUTPUT :YES
ALARM 3
SENSOR ENABLE:YES
SENSOR TYPE :N.O.
BUZZER ENABLE:YES
ALARM OUTPUT :YES