background image

Distributed by

TRANSWORLD AQUATIC ENTERPRISES, INC.

TEL

:(310)672-0480

@

FAX

:(310)672-7261

w w w . j b j l i g h t i n g . c o m

2 0 0 6 . 0 5

Summary of Contents for DBA-075

Page 1: ...672 0480 FAX 310 672 7261 w w w j b j l i g h t i n g c o m SPECIFICATIONS TI TITANIUM CHILLER Power Supply 115Volt 60Hz IC Electronic Temperature Controller Ozone Friendly Refrigerant R 134a DBA 150...

Page 2: ...4 INSTALLATION 4 1 Installation to Aquarium or Tank 4 2 How to Connect Hose 5 GETTING STARTED 5 1 Start Up 6 MAINTENANCE 6 1 Operation To Be Carried Out Every 6 Months Table 1 Chiller Speifications Fi...

Page 3: ...It should not be plugged in if there is water on parts not intended to be wet 3 Do not operate any appliance if it has a damaged cord or plug or if it is malfunctioning or has been dropped or damaged...

Page 4: ...the outlet reverse the plug If it still does not fit contact a qualified electrician Never use with an extension cord unless plug can be fully inserted Do not attempt to defeat this safety feature l M...

Page 5: ...66 lbs 142 2 298 6 PSIG Serial NO Model Power Supply Compressor Hp Output Rating Condition Input Amperes Cooling Amps Watts Refrigerant T otal Charge Design Pressure Lo Hi 3 000 BTU h Cooling Capacit...

Page 6: ...led damage notation If you give the carrier aclear receipt for the goods that have been damaged or lost in transit you do so at your own risk and expense The manufacturer is willing to assist you in c...

Page 7: ...east 1 foot clearance for air flow The chiller must have proper air flow to function correctly DO NOT PLACE INSIDE AQUARIUM STANDS THAT ARE ENCLOSED 5 Hose Tubing Not Included Connector Cork Stopper R...

Page 8: ...rs Indication Descriptions Overcooling Short circuit Short circuit Abnormal signal of sensor Please try to check and repair it following instructions below Otherwise contact us for warranty service Pl...

Page 9: ...Carried Out Every 6 Months UCleaning of the condenser Remove the suction grill and clean the ribbed condenser fins with a vacuum cleaner or jet of air to clean dust and debris from impeding air flow...

Page 10: ...5 DBA 150 DBE 200 DBM 250 Figure 1 Electrical Diagram TEMPERATURE CONTROLLER CHILLER COMP FAN PCB O L P C PTC INPUT VOLTAGE AC115V 1Ph 60Hz POWER INLET FUSE TEMP SENSOR CONECTOR 2P CONECTOR MALE 4P SK...

Page 11: ...Name for Chiller 9 Water temperature or setting temperature factory set 77 Cooling lamp UP button DOWN button Temperature controller Temperature controller Suction grill Suction grill Exhaust grill Ex...

Page 12: ...200 TEMPERATURE CONTROLLER GRILL HOSE ELBOW SOCKET 1 RUBBER GASKET 1 SOCKET 2 RUBBER GASKET 2 CASE CHILLER RUBBER GASKET SOCKET 3 FAN BLADE FAN MOTOR ASS Y 1 FAN BLADE 2 MOTOR 3 BRACKET CONDENSER REFR...

Page 13: ...TROLLER GRILL HOSE ELBOW SOCKET 1 RUBBER GASKET 1 SOCKET 2 RUBBER GASKET 2 1 CASE 1 2 CASE 2 3 CASE 3 CHILLER RUBBER GASKET SOCKET 3 FAN BLADE FAN MOTOR ASS Y 1 FAN BLADE 2 MOTOR 3 BRACKET CONDENSER R...

Page 14: ...Distributed by TRANSWORLD AQUATIC ENTERPRISES INC TEL 310 672 0480 FAX 310 672 7261 w w w j b j l i g h t i n g c o m 2 0 0 6 0 5...

Reviews: