1.                              Without timer setting,the 

operation mode is Cooling,Dry, Fan and Auto,and 

the set temperature will be displayed.

Time will be displayed under timer setting.

Digital Display:

3.                             Turn the air conditioner on and 

off.

Power Button:

                          Press the mode button to cycle

through the various modes: Cool, Dry, Fan and

Auto.

4.

Mode Button:

1

2

3

4

5

6

7

8

9

AUTO

SPEED

AUTO

MODE

You may hear a pinging noise caused by water 

hitting the condenser on rainy days, or when the 

humidity is high. The design features help remove 

moisture and improve efficiency.

Cool Mode:

 The cooling function allows the air 

conditioner to cool the room and at the same time 

reduces humidity. Press the MODE button to 

activate the cooling function. To optimize this 

function, adjust the temperature by pressing the 

up and down arrows and the speed by pressing 

the Fan Speed button.

Dry Mode: 

This function reduces the humidity of 

the air to make the room more comfortable. Press 

MODE button to set the DRY mode.

Fan Mode:

 This mode will only circulate the air. 

Press MODE button to select FAN MODE. 

Pressing the FAN SPEED button allows you to 

change the fan speed setting from HI, MED and 

LO. If using the remote control, it will store the fan 

speed setting from the most previous use.

Auto Mode:

 In AUTO mode the unit automatically 

chooses the fan speed and the mode of operation 

(COOL, DRY or FAN). In this mode the fan speed 

and temperature are set automatically according 

to the room temperature (Room temperature is 

determined by the temperature sensor located in 

the unit.)

    and      Button: 

Use these buttons on the

control panel and remote to increase or decrease

the Set Temperature or Timer. Temperature

range is between 61°F and 8°F

(16°C-31°C).

2.

^

^

5.

          

Timer 

                  

Button:

        

Use t

hese 

buttons 

on the control

panel and remote to set the 

T

imer.

Timer Off:

 

The 

timed stop is programmed 

by

pressing the 

TIMER

 

button. Set 

the 

 

time 

by

 

pressing the 

button 

or 

, set the temperature with pressing 

Timer On:

button 

first

the 

button 

or 

 with pressing the 

button 

or 

.

stop

until 

your 

desired stop time is 

displayed, 

then press 

TIMER 

button 

again.

 

When 

the unit is off, press 

TIMER

 

Press 

TIMER button 

a second time, set the stop time

 

Press 

TIMER button

 a 

third time, confirm your settings and stop time.

 

The display will show the time your machine will

 

automatically turn on.

Note: 

It can be set to automatically turn off or on 

in 0.5-24 hours. Each press of the

buttons will increase or decrease the timer. The 

Timer can be set in 0.5 hours increment below 10 

hours and 1 hour increment for 10 hours or 

above. The SET light will turn on while setting. 

To cancel the set function, press the TIMER 

button again.

Summary of Contents for 2AW8000DA

Page 1: ...WINDOW AIR CONDITIONER MODEL 2AW8000DA OWNER S MANUAL ...

Page 2: ...__________________________ Pur Purchase Date chase Date ____________________________________ ____________________________________ Stor Store Pur e Purchased chased _____________________________________ _____________________________________ Installation Date Installation Date ___________________________________ ___________________________________ Installation Co Installation Co ____________________...

Page 3: ...PORTANT SAFETYINSTRUCTIONS INSTALLATION HARDWARE INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND MAINTENANCE TROUBLESHOOTING ELECTRICAL REQUIREMENTS 2 3 INTRODUCTION TO REFRIGERANTS R32 1 11 13 14 15 ...

Page 4: ... open flames an operating ignition gas appliance or an operating electric heater Please contact the nearest after sale service center when maintenance is necessary At the time of maintenance the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non professional is prohibited to maintain the air conditioner The handling installat...

Page 5: ...ONT FCC Caution This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any Changes ormodifications not expressly approved by the party responsible for compliance could void the user s auth...

Page 6: ...ay fuse or Electrical Shock Hazard Plug into a grounded 3 prong outlet Do Not remove the ground prong Do Not use an adapter Do Not use an extension cord Failure to follow these instructions can result in death fire or electrical shock ...

Page 7: ...on for the Accordion Panels Thin sponge for back up using Insulation Strip Foam Only for E Star models TOOLS NEEDED Phillips Head Screwdriver Flat Head Screwdriver Drill 3 16ʺ Drill Bit Pencil Tape Measure Scissors or Knife Level NOTE Save carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use INSTALLATION HARDWARE ...

Page 8: ...SILL INTERIOR WALL EXTERIOR WALL Only used for 8K NOTE Save the product packaging and installation instructions for future reference Store the air conditioner in the product box when not in use for an extended period of time ...

Page 9: ...e unit on the floor a bench or a table There is a Left and Right Accordion Panel be sure to use the proper panel for each side When installed the flange for securing the panel in place to the window will be facing into the room CONT ...

Page 10: ...7 Suggest to keep a downward oblique to let accumulated rain water to drain out from back side of the unit bottom FIG 6 FIG 7 FIG 8 FIG 9 FIG 10 FIG 11 FIG 12 FIG 13 CONT ...

Page 11: ...8 FIG 14 CONT ...

Page 12: ...m or A 1 8 m for wall mounted 0 max min Table GG 1 Maximum charge kg Category LFL 3 kg m h0 m 2 Floor area m Category LFL 3 kg m h0 m Charge amount M kg 2 Minimum room area m 2 Table GG 2 Minimum room area m Before installing the appliance you must read the manual carefully to get the safety information and notes When filling the combustible refrigerant any of your rude operations may cause seriou...

Page 13: ...ures such as wear anti static clothing and or gloves 4 It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and or explosive environment 5 If the indoor unit suffers refrigerant leak during the installation all the personnel sh...

Page 14: ...g from the most previous use Auto Mode In AUTO mode the unit automatically chooses the fan speed and the mode of operation COOL DRY or FAN In this mode the fan speed and temperature are set automatically according to the room temperature Room temperature is determined by the temperature sensor located in the unit and Button Use these buttons on the control panel and remote to increase or decrease ...

Page 15: ...rature and fan speed to make the room more comfortable during the night The set temperature will automatically change every 30 60 minutes and at most change six times until the set temperature is 81 or 82 F Press the FAN SPEED button to select the fan speed In COOL MODE you can choose the following settings D E M I H LO or AUTO In Fan MODE you can choose from HI MED and LO O 1 ...

Page 16: ...COOL DRY FAN and HEAT Note The HEAT mode is inactive for COOL ONLY models Press and hold the MODE button for more than 5 seconds to delete or add the HEAT mode on remote Press the FAN speed button to select the fan options You can choose HI MED LO or AUTO in COOL MODE or HEAT MODE and HI MED LO in FAN MODE 1 ...

Page 17: ...an unplug the air conditioner to prevent shock or fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or wiped down with a damp cloth in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Never use harsh cleaner wax or polish on the front of the cabinet To store the air conditioner when it is not in use for ...

Page 18: ...15 The temperature setting may not be set correctly Battery Size AAA NOTE Do not mix old and new batteries or different types of AAAbatteries ...

Page 19: ...commended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 minutes It is also recommended to try another wall outlet For further assistance contact Consumer Services at 855 663 9463 ...

Page 20: ...855 663 9463 support arcticwindac com www arcticwindac com 5401 Dansher Road Countryside IL 60525 Printed in China 0121_M528 ...