background image

4

Remote Control

(With 2 AAA Batteries)

Top Mounting Rail 

(With foam)

Lock Frame

Accordion Panels 

(With "Left" & "Right" remark 

on the front face)

Sash Lock 

(Two holes)

Window Sash Seal 

(Foam)

3/8" Screws 

1/2" Screws

3/4" Screws

QTY.

Insulation for the 

Accordion Panels

(Thin sponge for back-up using)

Insulation Strip 

(Foam)

 (Only for E-Star models)

TOOLS NEEDED

Phillips Head 

Screwdriver

Flat Head 

Screwdriver

Drill & 3/16

ʺ

 Drill Bit

 

Pencil

Tape

 Measure

 

Scissors or

 Knife

 

Level

NOTE: Save carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter or when not in use.

INSTALLATION HARDWARE INCLUDED

I FEEL

ECO

FA

N

<

<

Summary of Contents for 2AW8000DA

Page 1: ...WINDOW AIR CONDITIONER MODEL 2AW8000DA OWNER S MANUAL ...

Page 2: ...__________________________ Pur Purchase Date chase Date ____________________________________ ____________________________________ Stor Store Pur e Purchased chased _____________________________________ _____________________________________ Installation Date Installation Date ___________________________________ ___________________________________ Installation Co Installation Co ____________________...

Page 3: ...PORTANT SAFETYINSTRUCTIONS INSTALLATION HARDWARE INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND MAINTENANCE TROUBLESHOOTING ELECTRICAL REQUIREMENTS 2 3 INTRODUCTION TO REFRIGERANTS R32 1 11 13 14 15 ...

Page 4: ... open flames an operating ignition gas appliance or an operating electric heater Please contact the nearest after sale service center when maintenance is necessary At the time of maintenance the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non professional is prohibited to maintain the air conditioner The handling installat...

Page 5: ...ONT FCC Caution This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any Changes ormodifications not expressly approved by the party responsible for compliance could void the user s auth...

Page 6: ...ay fuse or Electrical Shock Hazard Plug into a grounded 3 prong outlet Do Not remove the ground prong Do Not use an adapter Do Not use an extension cord Failure to follow these instructions can result in death fire or electrical shock ...

Page 7: ...on for the Accordion Panels Thin sponge for back up using Insulation Strip Foam Only for E Star models TOOLS NEEDED Phillips Head Screwdriver Flat Head Screwdriver Drill 3 16ʺ Drill Bit Pencil Tape Measure Scissors or Knife Level NOTE Save carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use INSTALLATION HARDWARE ...

Page 8: ...SILL INTERIOR WALL EXTERIOR WALL Only used for 8K NOTE Save the product packaging and installation instructions for future reference Store the air conditioner in the product box when not in use for an extended period of time ...

Page 9: ...e unit on the floor a bench or a table There is a Left and Right Accordion Panel be sure to use the proper panel for each side When installed the flange for securing the panel in place to the window will be facing into the room CONT ...

Page 10: ...7 Suggest to keep a downward oblique to let accumulated rain water to drain out from back side of the unit bottom FIG 6 FIG 7 FIG 8 FIG 9 FIG 10 FIG 11 FIG 12 FIG 13 CONT ...

Page 11: ...8 FIG 14 CONT ...

Page 12: ...m or A 1 8 m for wall mounted 0 max min Table GG 1 Maximum charge kg Category LFL 3 kg m h0 m 2 Floor area m Category LFL 3 kg m h0 m Charge amount M kg 2 Minimum room area m 2 Table GG 2 Minimum room area m Before installing the appliance you must read the manual carefully to get the safety information and notes When filling the combustible refrigerant any of your rude operations may cause seriou...

Page 13: ...ures such as wear anti static clothing and or gloves 4 It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and or explosive environment 5 If the indoor unit suffers refrigerant leak during the installation all the personnel sh...

Page 14: ...g from the most previous use Auto Mode In AUTO mode the unit automatically chooses the fan speed and the mode of operation COOL DRY or FAN In this mode the fan speed and temperature are set automatically according to the room temperature Room temperature is determined by the temperature sensor located in the unit and Button Use these buttons on the control panel and remote to increase or decrease ...

Page 15: ...rature and fan speed to make the room more comfortable during the night The set temperature will automatically change every 30 60 minutes and at most change six times until the set temperature is 81 or 82 F Press the FAN SPEED button to select the fan speed In COOL MODE you can choose the following settings D E M I H LO or AUTO In Fan MODE you can choose from HI MED and LO O 1 ...

Page 16: ...COOL DRY FAN and HEAT Note The HEAT mode is inactive for COOL ONLY models Press and hold the MODE button for more than 5 seconds to delete or add the HEAT mode on remote Press the FAN speed button to select the fan options You can choose HI MED LO or AUTO in COOL MODE or HEAT MODE and HI MED LO in FAN MODE 1 ...

Page 17: ...an unplug the air conditioner to prevent shock or fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or wiped down with a damp cloth in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Never use harsh cleaner wax or polish on the front of the cabinet To store the air conditioner when it is not in use for ...

Page 18: ...15 The temperature setting may not be set correctly Battery Size AAA NOTE Do not mix old and new batteries or different types of AAAbatteries ...

Page 19: ...commended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 minutes It is also recommended to try another wall outlet For further assistance contact Consumer Services at 855 663 9463 ...

Page 20: ...855 663 9463 support arcticwindac com www arcticwindac com 5401 Dansher Road Countryside IL 60525 Printed in China 0121_M528 ...