18
Onzen Technical Guide
Is Sanitizer Being Produced and Delivered to Spa Water?
This test requires:
· The water temperature to be at least 80º F (27º C).
· The Filter Cycle Duration to be set to 00.
· Onzen Cycle Duration programmed to On 24. Onzen system will run for 24 hours per day.
Step 1. Set Filtration Cycle Time to Fd 00 (= No Filtration)
Press the Filter Cycle Key until SETT is displayed.
The Filter Cycle Duration details “Fd” will be displayed “Fd XX” .
Use down arrow key to change the Filter Cycle
Duration to Fd 00.
This de-activates the filtration pump so you can see the mist of
gas bubbles produced by the Onzen System.
Step 2. Scroll to On (Onzen Duration) Setting
Scroll through the settings by pressing the Filter Cycle
key until it reads “On X ”. (“x” will be a value between
0 & 24).
Step 3. Change On Setting to On 24
Change On setting to On 24.
On 24 programs the Onzen system to produce sanitizer 24 hours daily.
Step 4. Scroll Through Settings
Continue scrolling through the settings by repeatedly pushing the
Filter Cycle key until the pack resets.