4
2.Technology Parameters
2.1 Parameters
Models
Parameters
ArcoCut 40i
Input power
single-phase
,
220V/110V
,
50/60Hz
Rated input current
(
A
)
23.4(220V)
33.7(110V)
Rated input power
(
KW
)
4.63(220V)
3.44(110V)
Adjustment range of current
(
A
)
20
~
40(220V)
20
~
30(110V)
Max no-load voltage(V)
480
Duty cycle
(
40
℃
,
10 minutes
)
40%(220V)
35%(110V)
Note: The above parameters are subject to change with the improvement of machines.
3.1 Unpacking
3 Installation
1. Use the packing lists to identify and account for each item.
2. Inspect each item for possible shipping damage. If damage is evident, contact your distributor and/or shipping
company before proceeding with the installation.
3.2 Input Power Connections
Note: Check your power source for correct voltage before plugging in or connecting the unit
3. 3 Air Connections
A.
Connecting Air Supply to Unit
Connect the air-line to the inlet port of the air filter on the rear panel.
B.
Check Air Quality
To test the quality of air, put the RUN / SET switch in the SET (down) position, check if there is any oil or moisture in
the air.
Summary of Contents for ArcoCut G-40i