17
&Fn Load Factory Settings
This command loads the configuration stored and programmed at the factory.
This operation replaces all of the command options and the S-register settings
in the active configuration with factory values.
&Gn V.22bis Guard Tone Control
This command determines guard tone frequency and is only used in V.22 and
V.22bis mode. This option is not used in North America and is for international
use only.
&G0*
Guard tone disabled.
&G1
Sets guard tone to 550 Hz.
&G2
Sets guard tone to 1800 Hz.
Result Codes:
OK
n = 0, 1, 2
ERROR
Otherwise
&Kn Local Flow Control Selection
&K0
Disable flow control.
&K1
Reserved.
&K2
Reserved.
&K3
Enable RTS/CTS flow control.
&K4
Enable XON/XOFF flow control.
&K5
Enable Transparent XON/XOFF flow control.
Result Codes:
OK
n = 0,1,2, 3, 4
ERROR
Otherwise
&Pn Pulse Dial Make-to-Break Ratio Selection
&P0*
39/61 make-to-break ratio (10 pps).
&P1
33/67 make-to-break ratio 10 pps).
&P2
39/61 make-to-break ratio (20 pps)
&P3
33/67 make-to-break ratio (20 pps)
Result Codes:
OK
n = 0, 1
ERROR
Otherwise