25-BVI20N
–
3 9
MINIMUM MASONRY FIREPLACE DIMENSIONS
17” (432
mm)
25” (635
mm)
12” (305
mm)
TOP VIEW
The standard flue adapter will fit if
X
is more than 5
¾
”.
It will also fit if
X
is less than 5
¾
”
but
Y
is
higher than
8”
(See
‘
Flue connector, offset vent
’
diagram)
19
½
” (495
mm)
SIDE VIEW
X
Y
Z
Flue connector
straight
-
up vent
Flue connector
offset vent
Flue connector
straight
-
up vent
Flue connector
offset vent
INSTALLATION INSTRUCTIONS
-
Continued
WARNING: Failure to position the parts in accordance with these diagrams or failure to use
only parts specifically approved with this appliance may result in property damage or personal
injury.
The installer must mechanically attach the following warning (included in the manual bag) to the inside of the fire-
box of the fireplace into which the gas fireplace insert is installed.
WARNING:
This fireplace has been converted for use with a gas fireplace insert only and cannot be used for
burning wood or solid fuels, unless all original parts have been replaced, and the fireplace reap-
proved by the authority having jurisdiction.
AVERTISSEMENT:
Ce foyer a ete converti pour utilisation avec un foyer au gaz encastrable et ne peut etre utiliser pour
bruler du bois ou autres combustibles solides a moins que toutes les pieces d'origine ete rem-
placees et que le foyer ait ete approuve de nouveau par l'autorite competente.