Due to high temperatures, the appliance should be located out of traffic and away from 

furniture and draperies

 

• 

Children and adults should be alerted to the hazards of high surface temperature and stay 

away to avoid burns or clothing ignition

 

• 

Young children should be carefully supervised when they are in the same room as the 

appliance

 

• 

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with 

this appliance and shall be installed for the protection of children and other at

-

risk 

individuals

 

• 

Clothing or other flammable material should not be placed on or near the appliance

 

• 

Maintain adequate clearances around air openings into the combustion chamber

 

• 

Flow of combustion or ventilation air must not be obstructed

 

• 

Any parts removed or opened for servicing of the appliance must be properly replaced prior 

to operating the appliance

 

• 

The appliance must be inspected before use and at least annually by a qualified service 

person. More frequent cleaning may be required due to excessive lint from carpeting, 

bedding material, etc. It is imperative that the control compartments, burners and circulating 

air passageways for the appliance be kept clean

 

• 

Trim panels or surrounds shall not seal ventilation openings in the fireplace

 

CAUTION

 

• 

FOR YOUR SAFETY 

-

 Do not install or operate your Archgard Euro 25 Gas Fireplace Insert 

Heater without reading and understanding this manual. Any installation or operational 

deviation from this instruction manual voids the Archgard Industries Ltd. Warranty and may 

prove hazardous

 

• 

Installation and repair should be done by a qualified service person. The appliance should be 

inspected before use and at least annually by a professional service person. More frequent 

cleaning might be required due to excessive lint from carpeting, bedding material, et cetera. 

It is imperative that control compartments, burners, and circulating air passageways of the 

appliance be kept clean

 

• 

This appliance must be installed by a qualified gas installer and the installation must 

conform to the installation codes

 

• 

Provide adequate clearance around air openings of the appliance

 

• 

Never obstruct front openings

 

• 

Provide adequate clearances for proper operation and servicing of the appliance

 

• 

This appliance must be properly connected to an approved venting system and must not be 

connected to a chimney flue serving a separate solid fuel burning appliance

 

 

SAFETY 

 

Summary of Contents for 25-BVI20N-3

Page 1: ...and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave...

Page 2: ...or of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accord...

Page 3: ...thetics and heat output can be adjusted to suit the owner s moods and heating needs Solid Construction Constructed mainly of 16 and 18 gauge satin coated steel for long life and durability Please read...

Page 4: ...ns 8 Log Placement 15 Operation Instructions 20 Maintenance 22 Troubleshooting Instructions 23 Servicing 25 APPENDIX A Installation Into Vented Gas Fireplaces 28 Suitable Host Fireplaces Specific Inst...

Page 5: ...compartments burners and circulating air passageways for the appliance be kept clean Trim panels or surrounds shall not seal ventilation openings in the fireplace CAUTION FOR YOUR SAFETY Do not insta...

Page 6: ...nstallation in a bedroom or a bedsitting room and conforms to CR89 001 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National...

Page 7: ...S BAY GLASS DOOR REMOVABLE CONTROL COVER SURROUND FRONT VIEW SPARKER APPLIANCE DIMENSIONS A B I K J A 30 768 mm B 23 584 mm C 15 387 mm D 11 286 mm E 4 102 mm F 19 489 mm G 5 127 mm H 5 146 mm I 24 61...

Page 8: ...y factory built wood burning and specific zero clearance vented gas fireplaces Due to constant additions contact Archgard Industries for an updated list of suitable gas fireplaces This appliance canno...

Page 9: ...esult in property damage or personal injury The installer must mechanically attach the following warning included in the manual bag to the inside of the fire box of the fireplace into which the gas fi...

Page 10: ...ust not be removed or altered side and top of door frame side and top of the face of fireplace metal sides etc If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2...

Page 11: ...ng and possible death This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance The appliance may be vented using 4 in diameter aluminum or stainless steel...

Page 12: ...flat tip screw driver and placing a test gauge on the tap The minimum permissible gas supply pressure is 4 5 in w c 1 2 kPa for natural gas and 11 0 in w c 2 8 kPa for propane Maximum gas supply press...

Page 13: ...es on the bracket that best suit your application INSTALLATION INSTRUCTIONS Continued 1 2 3 The spill switch is manual reset type that can be reset by pressing the pin between the two wire terminals w...

Page 14: ...bottom of the door towards you Lift up the door to unhook it from the body Place the door at a safe location where it cannot be scratched or damaged Replacing the Glass Door Installation of the glass...

Page 15: ...an the amount and type supplied with the unit LOG PLACEMENT WARNING Do not place the logs or branches in any configuration other than the one shown A fire explosion or excessive carbon monoxide CO may...

Page 16: ...rt using locator pins and pre drilled holes in log Log will sit as shown in the photo below STEP 2 Locate log 2 and place onto the left side of the burner using locator pins and pre drilled holes in l...

Page 17: ...er using the locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 4 Locate log 4 and place onto right side of burner using the locator pins and pre drilled holes in lo...

Page 18: ...he locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 6 Locate log 6 and place onto rear log using the locator pins and pre drilled holes in log Log should sit behin...

Page 19: ...place onto rear log using the locator pins and pre drilled holes in log Log should sit behind left grate tine as shown in photo below FINAL LOG PLACEMENT Please note that all logs should be placed ex...

Page 20: ...lt in a fire or explosion BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SME...

Page 21: ...ing of pilot Press slightly and turn control knob counterclockwise to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place at the pilot...

Page 22: ...gular services listed above Inspect and operate the pressure relief mechanism door buckles to verify they are free from ob struction and operate properly Carefully remove the logs and gently brush off...

Page 23: ...ay be blocked or the gas valve may be defective 5 Check wiring and connections to spill switch Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob...

Page 24: ...for correct ohms reading Replace if required 7 Check for proper drafting of the appliance Correct if drafting is occurring into the room 8 Spill switch has tripped Reset by hand when appliance has coo...

Page 25: ...CING UNDER WARRANTY Remove the control cover The pressure test taps are located on the front of the valve The supply pressure is marked IN and the manifold pressure is marked OUT There is also an arro...

Page 26: ...now visible Use a 11 32 hex socket and remove the three nuts holding the fan to the back of the firebox Disconnect the spade connectors to the fan Carefully remove the fan Reverse the above instructio...

Page 27: ...r tray by loosening and removing the two mounting screws located next to the two back log locating tabs Shut of the gas to the appliance and disconnect the gas line to the appliance If the appliance h...

Page 28: ...n updated list of gas fireplaces and any additional installation instructions The host gas fireplace s certification will be nullified and will no longer be usable for its original purpose A warning p...

Page 29: ...ox Remove or trim any baffles inside the firebox that may be obstructing the direct passage to the flue connector Remove or trim any decorative facing or baffles inside the firebox that may interfere...

Page 30: ...O 25 as it is being inserted into the host fireplace Level the EURO 25 as described in manual Complete the installation of the surround and accessories as described in the manual Check for proper vent...

Page 31: ...personal injury or loss of life SAMPLE MODIFICATION WARNING PLATE 303 0050 WARNING This fireplace has been modified for use with the Archgard EURO 25 gas insert Usage without the EURO 25 gas insert m...

Page 32: ...on of the host gas fireplace is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 7 Use Ar...

Page 33: ...of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 6 Use Archgard 25 ICKIT5 connector kit to connect the insert to...

Page 34: ...also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the hos...

Page 35: ...is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector k...

Page 36: ...chgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the host s vent cap Optional custom surround is availabl...

Page 37: ...NAME ADDRESS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER 25 BVI20N 3 SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE Robertshaw 7000MVRB DATE PURCHASED INSTALLATION INSTAL...

Page 38: ...ve When calling for help please have the following information Model of your Fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty may be void if work is carried...

Page 39: ...0044 SPILL SWITCH 350 F MANUAL RESET 1 EA 305 0027 SWITCH BLANK ON OFF CARLING 9711 1 EA 308 0005 PIEZO IGNITOR c w NUT JBS 66270 003 1 EA 308 0043 VALVE 7000MVRB 5LC NG c w KNOB 1 EA 308 0093 PILOT A...

Page 40: ...25 BVI20N 3 40 NOTES...

Page 41: ...ler s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this wa...

Page 42: ......

Page 43: ...25 BVI20N 3 43 NOTES...

Page 44: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...