Archgard 25-BVI20N-3 User'S Installation, Operation And Maintenance Manual Download Page 38

 

 

 

This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as 

Archgard

”. 

Archgard warrants to the 

original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workmanship under 

normal use and service, for a 

lifetime

”.

 

 

INCLUSIONS: 

LIFETIME LIMITED WARRANTY

 

 

All heat exchangers, combustion chamber, burner tubes and pans.  

 

 

Ceramic Fiber Logs and Ceramic Brick Panels against splitting or cracking.

 

 

Ceramic Glass against thermal breakage..

 

 

NOTE: Discoloration and some minor movement of certain parts are normal and are not a defect and therefore, not covered under 

warranty.  

 

The above will be covered 

parts & labor

” 

to the original purchaser for FIVE years and 

parts

” 

only thereafter from original date of pur-

chase.

 

 

INCLUSIONS: 

ONE YEAR LIMITED WARRANTY

” 

 

 

Blowers, fans and fan motors, wiring, rheostats and thermodiscs.

 

 

Rocker switches, spill switches and wiring to them. 

 

 

Gas control valves, pilot assemblies including thermopiles, thermocouples, electrodes, and igniters.

 

 

All 24 K gold trims and accessories against tarnishing.

 

All trim accessories against tarnishing and paint defects

 

The above will be covered 

parts & labor

”  

to the original purchaser for ONE year from date of purchase. 

 

 

EXCLUSIONS:

 

 

Archgard does not offer wall mounted thermostats, programmable thermostats (wiring for hook

-

up of said product), handheld remote 

controls, fireplace mantel (s), trims or tiles. 

 

 

Ember Material.

 

 

Tempered Glass is warranty for ONE year to the original purchaser from date of purchase.

 

 

Travel time or mileage to original purchasers residence. Archgard suggests that you pre

-

arrange travel expenses with your Authorized 

Archgard Dealer.

 

 

 

WHAT TO DO IN THE EVENT OF A PROBLEM:

 

 

Thoroughly read your manual.

 

 

If you cannot solve the problem, contact your Archgard Dealer or representative. 

 

 

When calling for help please have the following information: 

 

            

Model of your Fireplace

 

Serial Number

 

Place of Purchase                           

 

            Date of Purchase

 

Problem Description

 

 

NOTE: Warranty may be void if work is carried out by an unqualified person (s). Only original Archgard parts may be used. Please 

consult your Archgard dealer or representative if in doubt about a replacement part (s).

 

 

OBTAINING WARRANTY SERVICE:

 

To obtain warranty service, the original purchaser shall return the defective part (s) to the original authorized Archgard selling dealer 

transportation prepaid, along with the serial number of the appliance and proof of purchase. Any defective part, in our 

 

judgment, will be repaired or replaced at Archgard

s discretion. The dealer must obtain approval from Archgard before any 

 

repairs are made. 

 

 

WARRANTY LIMITATION:

 

THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED AS TO QUALITY, 

MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE.

 

 

The appliance is only warranted for the use as intended by the installation and operating instruction and local building codes. The warran-

ty will not cover damage due to accident, misuse, abuse, alteration, improper installation or 

Acts Of God

”. 

 

This limited warranty is void unless the appliance is installed by a qualified installer, in accordance with the instructions 

 

furnished with the appliance. Some Provinces or States do not allow limitations on how long an implied warranty lasts, so the above limi-

tation may not apply to the original purchaser. Any damage resulting from defects in this product, is limited to the 

 

replacement of the defective part (s) and does not include incidental and consequential exposures sustained in connection with the prod-

uct. This includes facing (s),   mantle (s), cabinet (s), tile (s) or any other finishes resulting from removal of any gas appliance. This war-

ranty is limited to residential use only and gives the consumer specific rights. These rights may vary from State to State or Province to 

Province. 

 

ARCHGARD LIMITED WARRANTY 

Summary of Contents for 25-BVI20N-3

Page 1: ...and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave...

Page 2: ...or of the side wall horizontally vented gas fueled equipment shall not approve the instal lation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accord...

Page 3: ...thetics and heat output can be adjusted to suit the owner s moods and heating needs Solid Construction Constructed mainly of 16 and 18 gauge satin coated steel for long life and durability Please read...

Page 4: ...ns 8 Log Placement 15 Operation Instructions 20 Maintenance 22 Troubleshooting Instructions 23 Servicing 25 APPENDIX A Installation Into Vented Gas Fireplaces 28 Suitable Host Fireplaces Specific Inst...

Page 5: ...compartments burners and circulating air passageways for the appliance be kept clean Trim panels or surrounds shall not seal ventilation openings in the fireplace CAUTION FOR YOUR SAFETY Do not insta...

Page 6: ...nstallation in a bedroom or a bedsitting room and conforms to CR89 001 We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National...

Page 7: ...S BAY GLASS DOOR REMOVABLE CONTROL COVER SURROUND FRONT VIEW SPARKER APPLIANCE DIMENSIONS A B I K J A 30 768 mm B 23 584 mm C 15 387 mm D 11 286 mm E 4 102 mm F 19 489 mm G 5 127 mm H 5 146 mm I 24 61...

Page 8: ...y factory built wood burning and specific zero clearance vented gas fireplaces Due to constant additions contact Archgard Industries for an updated list of suitable gas fireplaces This appliance canno...

Page 9: ...esult in property damage or personal injury The installer must mechanically attach the following warning included in the manual bag to the inside of the fire box of the fireplace into which the gas fi...

Page 10: ...ust not be removed or altered side and top of door frame side and top of the face of fireplace metal sides etc If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2...

Page 11: ...ng and possible death This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance The appliance may be vented using 4 in diameter aluminum or stainless steel...

Page 12: ...flat tip screw driver and placing a test gauge on the tap The minimum permissible gas supply pressure is 4 5 in w c 1 2 kPa for natural gas and 11 0 in w c 2 8 kPa for propane Maximum gas supply press...

Page 13: ...es on the bracket that best suit your application INSTALLATION INSTRUCTIONS Continued 1 2 3 The spill switch is manual reset type that can be reset by pressing the pin between the two wire terminals w...

Page 14: ...bottom of the door towards you Lift up the door to unhook it from the body Place the door at a safe location where it cannot be scratched or damaged Replacing the Glass Door Installation of the glass...

Page 15: ...an the amount and type supplied with the unit LOG PLACEMENT WARNING Do not place the logs or branches in any configuration other than the one shown A fire explosion or excessive carbon monoxide CO may...

Page 16: ...rt using locator pins and pre drilled holes in log Log will sit as shown in the photo below STEP 2 Locate log 2 and place onto the left side of the burner using locator pins and pre drilled holes in l...

Page 17: ...er using the locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 4 Locate log 4 and place onto right side of burner using the locator pins and pre drilled holes in lo...

Page 18: ...he locator pins and pre drilled holes in log Log should sit as shown in photo below STEP 6 Locate log 6 and place onto rear log using the locator pins and pre drilled holes in log Log should sit behin...

Page 19: ...place onto rear log using the locator pins and pre drilled holes in log Log should sit behind left grate tine as shown in photo below FINAL LOG PLACEMENT Please note that all logs should be placed ex...

Page 20: ...lt in a fire or explosion BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SME...

Page 21: ...ing of pilot Press slightly and turn control knob counterclockwise to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air may take place at the pilot...

Page 22: ...gular services listed above Inspect and operate the pressure relief mechanism door buckles to verify they are free from ob struction and operate properly Carefully remove the logs and gently brush off...

Page 23: ...ay be blocked or the gas valve may be defective 5 Check wiring and connections to spill switch Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob...

Page 24: ...for correct ohms reading Replace if required 7 Check for proper drafting of the appliance Correct if drafting is occurring into the room 8 Spill switch has tripped Reset by hand when appliance has coo...

Page 25: ...CING UNDER WARRANTY Remove the control cover The pressure test taps are located on the front of the valve The supply pressure is marked IN and the manifold pressure is marked OUT There is also an arro...

Page 26: ...now visible Use a 11 32 hex socket and remove the three nuts holding the fan to the back of the firebox Disconnect the spade connectors to the fan Carefully remove the fan Reverse the above instructio...

Page 27: ...r tray by loosening and removing the two mounting screws located next to the two back log locating tabs Shut of the gas to the appliance and disconnect the gas line to the appliance If the appliance h...

Page 28: ...n updated list of gas fireplaces and any additional installation instructions The host gas fireplace s certification will be nullified and will no longer be usable for its original purpose A warning p...

Page 29: ...ox Remove or trim any baffles inside the firebox that may be obstructing the direct passage to the flue connector Remove or trim any decorative facing or baffles inside the firebox that may interfere...

Page 30: ...O 25 as it is being inserted into the host fireplace Level the EURO 25 as described in manual Complete the installation of the surround and accessories as described in the manual Check for proper vent...

Page 31: ...personal injury or loss of life SAMPLE MODIFICATION WARNING PLATE 303 0050 WARNING This fireplace has been modified for use with the Archgard EURO 25 gas insert Usage without the EURO 25 gas insert m...

Page 32: ...on of the host gas fireplace is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 7 Use Ar...

Page 33: ...of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 6 Use Archgard 25 ICKIT5 connector kit to connect the insert to...

Page 34: ...also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the hos...

Page 35: ...is complete See Appendix A of the Euro 25 manual for further instructions All installation requirements in the manual must also be carefully observed and followed 8 Use Archgard 25 ICKIT5 connector k...

Page 36: ...chgard 25 ICKIT5 connector kit to connect the insert to the host s B vent or connect a 4 diameter flexible aluminum gas vent from the insert to the host s vent cap Optional custom surround is availabl...

Page 37: ...NAME ADDRESS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER 25 BVI20N 3 SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE Robertshaw 7000MVRB DATE PURCHASED INSTALLATION INSTAL...

Page 38: ...ve When calling for help please have the following information Model of your Fireplace Serial Number Place of Purchase Date of Purchase Problem Description NOTE Warranty may be void if work is carried...

Page 39: ...0044 SPILL SWITCH 350 F MANUAL RESET 1 EA 305 0027 SWITCH BLANK ON OFF CARLING 9711 1 EA 308 0005 PIEZO IGNITOR c w NUT JBS 66270 003 1 EA 308 0043 VALVE 7000MVRB 5LC NG c w KNOB 1 EA 308 0093 PILOT A...

Page 40: ...25 BVI20N 3 40 NOTES...

Page 41: ...ler s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ Why did you choose this product Thank you for purchasing our product and filling out this wa...

Page 42: ......

Page 43: ...25 BVI20N 3 43 NOTES...

Page 44: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Reviews: