Technical Specifications
C
Technical specifications may be changed without notice to improve the quality
of the product.
C
The shapes in the guide are schematic and may not be in perfect harmony with the product.
C
The markings on the product or other printed the values declared in the documents are
determined in the laboratory environment are the values obtained. These values are based
on product usage and ambient conditions change.
*
EER and COP values are the energy consumption class, and TS EN 14511
measurement standards.
Cooling: Indoor temperature
27ºC KT, 19ºC YT / Outdoor Environment: 35ºC KT, 24ºC YT
Heating: Indoor temperature 20ºC KT, 15ºC YT / Outdoor Environment: 7ºC KT, 6ºC YT
**
SEER and SCOP values are the energy consumption class, and TS EN 14511 measurement
standards.
C
Catalog data are energy consumption values given according to standard test results.
Actual energy consumption may vary depending on the conditions in which the devices
are used.
dBA
dBA
dBA
kg
kg
Running Current (Nom/Maks)
Sound Power
Net Weight
Circuit Breaker
(Sleep)
Sound Pressure
Capacity
Energy Label
Power Input
Cooling
ŽŽůŝŶŐͬ,ĞĂƟŶŐ
ŽŽůŝŶŐͬ,ĞĂƟŶŐ
Cooling
Cooling
Cooling
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Cooling
EER/COP*
SEER/SCOP**
Power Supply
P Design
09325
12325
18325
Btu/h
9000
12000
18000
W
2638
3517
5275
Btu/h
11260
13648
19790
W
3300
4000
5800
kW
2,50
3,50
5,00
kW
3,50
3,50
3,90
W
656
1080
1562
W
800
1050
1611
W/W
3,81 / 4,13
3,24 / 3,81
3,20 / 3,60
W/W
7,0 / 4,0
6,6 / 4,0
7,0 / 4,3
-
A++ / A+
A++ / A+
A++ / A+
kWh/
\Ö
l
125 / 875
186 / 875
250 / 1270
lt/h
1,1
1,3
1,8
V , Ø , Hz
220-240, 1, 50 220-240, 1, 50
220-240, 1, 50
A
3,4 / 6,0
4,7 / 6,0
7,3 / 9,0
A
3,7 / 7,0
4,7 / 7,0
7,1 / 9,5
A
15
15
20
19
19
31
MODEL
(-10°C)
59
59
60
65
65
65
8,70
8,70
11,70
25,10
25,10
35,20