Troubleshooting Guide

In addition to the tips below, our YouTube channel is filled with 

informational videos that can help with issues that may arise while 

using your AccuFlo Soil Injector ISD.  YouTube.com/arborjet

o

Difficulty Injecting into compact or clay soil

§

Lift the device up about an inch so there is space under the nozzle and 
try again.  If that doesn’t work, try unclogging the nozzle ports with a 
thin hex key or a paper clip

o

Losing Prime on the backpack pump.  Pump continuously pumps but does not 
build pressure to the device. 

§

Turn the backpack unit off, disconnect supply line, point it back into the 
backpack reservoir and turn it back on.  Once the product is flowing 
again, turn the backpack back on and reconnect. 

§

When you have almost depleted your product, make sure to keep the 
backpack level so the pump can dispense all of the liquid

o

Leaks in tubing, valve, or cylinder connections.

§

In order to repair leaks, you must remove the steel housing to expose 
the underlying assemblies.  This will require two 7/16” wrenches for the 
lock nuts, and one 5/32” Allen Key for the Button Screws on the 
Housing Handle.  

§

Visit our YouTube Channel for a step-by-step disassembly guide

Summary of Contents for AccuFlo 070-3100

Page 1: ...USER MANUAL...

Page 2: ...ate the System 8 How to Flush Clean Store the System 12 Determining Volume and Number of Injection Sites 13 Calculating Dosage of Injection Sites 14 How to Convert to Spray and Drench Applications 15...

Page 3: ...4 Gallon Backpack 070 3100 Or AccuFlo Soil Injector ISD Kit 9 Gallon Roller Tank 070 3200 Soil Injector ISD Device Box 1 Modified 5 Speed FlowZone Backpack or Roller tank Box 2 Graduated Cylinder Adj...

Page 4: ...Tank Sprayer Overview Bulkhead Drain Line Quick Disconnect Supply Line Variable Speed Adjustment Knob FlowZone Typhoon 2 5V 5 Position Variable 4 Gallon Sprayer FlowZone Monsoon 2 5V 5 Position Varia...

Page 5: ...tplate over the base of the lance 2 Twist extender and nozzle tip onto threaded lance adapter using provided Footplate Wrench 3 Position footplate facing depending on preference and tighten footplate...

Page 6: ...t Battery Battery may require charge before operation 5 Connect Tubing coming from backpack to the female hose adapter on the supply line 6 Connect tubing coming from the lance to the quick connect bu...

Page 7: ...gs with a torque wrench calibrating the Cylinder and using a checklist to perform an audit of contents for every kit that ships out of our facility The checklist is initialed by the assembler and supe...

Page 8: ...lume in mL per injection site AccuFlo Soil Injector ISD Training Manual Dose Collar Knob When setting dosage make sure the top of the collar lines up with the desired dosing size 2 With the knob loose...

Page 9: ...lve toggle in neutral position 4 Activate Backpack pump by turning the Variable Speed dial clockwise to the highest setting When the backpack is first activated it will begin to prime the supply line...

Page 10: ...mesh strainer and submerge the tip into the reservoir so product doesn t spray or splash during priming When system is in the fill position the backpack pump will activate and fill to the pre set dosa...

Page 11: ...osition 8 Begin Injection process by inserting the nozzle tip into the soil and step on the footplate until it bottoms out on the ground floor Repeat steps 5 7 to fill dose and dispense into pre deter...

Page 12: ...300mL max capacity 4 Disconnect the Drain Line from the bulkhead fitting 5 Place injection end of lance into a bucket 6 Initiate the fill and inject cycle until water runs clear 7 Store AccuFlo Soil...

Page 13: ...plication You may also need to consider plant species geographical location or environmental soil conditions when considering how much product to inject When dosing calls for injection volumes indivis...

Page 14: ...ISD Training Manual It is not uncommon for the total volume to be an odd number so the applicator will have to find the ideal combination of injection sites and volume per injection to achieve the pr...

Page 15: ...is turned off before initiating the steps below 1 Have a bucket nearby in case there is any remaining fluid in the drain line and disconnect supply line junction and the Quick Disconnect fitting from...

Page 16: ...y pumps but does not build pressure to the device Turn the backpack unit off disconnect supply line point it back into the backpack reservoir and turn it back on Once the product is flowing again turn...

Page 17: ...Exploded Views Part Numbers...

Page 18: ...Contacting Arborjet arborjet Arborjet Inc 99 Blueberry Hill Rd Woburn MA 01801 Phone 781 935 9070 Fax 781 935 9080 info arborjet com...

Reviews: