5
Operation
5.1
Startup
Upon proper power application the Model 120A Power LED will illuminate green and the bootup process starts.
The clock will start off in the unlocked state (Red unlocked LED will be illuminated) and if there are no faults the
Locked LED and the Fault LED will be off.
If connected to the serial or config port with a terminal program you will see:
120A Main: 1.01-16
Boot: 1.00-10
FPGA: 1.00
Username:
>status
Receiver Version: SW=ROM CORE 3.01 (107888) HW=00080000
GNSS : GPS GLONASS Galileo BEIDOU
Tracked: 0 0 0 N/A
SN/O : 0 0 0 N/A
Not Yet Locked
Time Quality:
Time Local: 00/00/0000 00:00:00
Time UTC : 00/00/0000 00:00:00
Which will progress to:
>status
Receiver Version: SW=ROM CORE 3.01 (107888) HW=00080000
GNSS : GPS GLONASS Galileo BEIDOU
Tracked: 8 7 5 N/A
SN/O : 40 31 37 N/A
Locked
Time Quality: 100nS
Time Local: 05/06/2020 16:27:58
Time UTC : 05/06/2020 23:27:58
DST: auto -7:00
5.2
Reset
A recessed RESET button is located on the far right of end panel that contains the CONFIG PORT. This button is
used to reboot or set reset the unit to factory defaults.
•
Reboot: Soft power cycle. Does not change configuration.
̶
Press, hold until all LEDs are on, release.
•
Defaults: Reset configuration to factory defaults.
̶
Press,
hold until all LEDs flash, release.
Summary of Contents for 120A
Page 2: ......
Page 6: ......
Page 9: ...7 5 Glossary 34 7 6 Drawings 35 ...
Page 35: ...7 6 Clock Drawings ...