ARANA T1000 Installation And Operating Instructions Manual Download Page 28

32

www.arana.com.cn

服务热线 : 

400 110 1890

版权所有,侵权必究

阿雷纳科技(深圳)有限公司

保留随时修改价格、材料、规格和型号的权利

或停止任何产品型号的生产 , 恕不另行通知

All rights reserved.

ARANA TECH (Shenzhen) Co., Ltd.

reserves the right to modify at any time 

without notice, prices, materials, 

specifications and models or to cease

production of any model.

RV CEILING F

ANS.0920.

V001

Summary of Contents for T1000

Page 1: ...Make A Difference 卓 尔 不 凡 CEILING FANS T1000 T2000 T3000 T5000 CN EN 房车换气扇 安装和使用说明书 Installation and Operating Instructions RV Powered Ceiling Fans ...

Page 2: ...说明书中的具体内容 1 0 安装说明 3 1 1 手动打开换气扇控制按键 适用于 T1000 T2000 2 0 安装步骤 适用于所有型号 3 2 自动打开换气扇 适用于 T3000 T5000 3 0 操作指南 3 2 1 自动打开换气扇控制按键 适用于 T3000 T5000 3 1 手动打开换气扇 适用于 T1000 T2000 3 3 遥控器操作说明 3 4 其他特殊功能 03 08 03 09 08 10 08 11 13 TABLE OF CONTENT 目录 ...

Page 3: ... Make A Difference 卓 尔 不 凡 CN 基本要求 1 0 安装说明 2 0 安装步骤 适用于所有型号 开孔尺寸 360 360mm 车顶厚度要求 48 134mm 电源要求 直流 12V 在将 12V 直流电源连接到换气扇之前 请断开车辆电源 1 需要一个 360 360mm 的屋顶开口 如果是替换其他换气扇 请清除车顶原来的密封胶 见图 1 注意 1 360mm 3 6 0 m m ...

Page 4: ...04 CN 2 在将换气扇安装到车顶之前 在法兰底部用丁基胶带或等效的密封胶 确保覆盖螺丝孔 见图 2 3 将车辆的 12V 电源连接到换气扇两根电线上 见图 3 换气扇连接到非 12V 直流电或者极性错误的电路都可能损坏换气扇 造成人身伤害及财产损坏 并 使保修无效 标记显示 的白色线必须接到车辆 12V 电源 注意 2 3 ...

Page 5: ...05 Make A Difference 卓 尔 不 凡 CN 4 将换气扇插入开口 盖子铰链面向车辆前部 换气扇对准开口 确保电源线在内部 使用提供的 M4 25 的螺丝 沿着法兰在凹圈位置将法兰固定在车辆顶部 将螺丝穿透法兰 力度适中以免法兰破裂 见图 4 4 ...

Page 6: ...06 CN 5 换气扇安装完毕后 密封法兰与车顶的缝隙 并且密封螺丝头 见图 5 车顶部分安装完成后 请接通车辆 12V 电源 听到滴声后 证明供电正常 如果接通 12V 直流电源后没 有听见滴声 请检查电源及换气扇连接线 如果还是不能正常运行请联系经销商 5 ...

Page 7: ...07 Make A Difference 卓 尔 不 凡 CN 6 根据车顶的厚度及内饰的高度调整内部装饰框 见图 6 7 用四个平头螺丝将装饰框固定在内部车顶 并将遮丑帽安装在平头螺丝上 见图 7 6 7 ...

Page 8: ...风扇 防虫纱网 抓住边框逆时针旋转可以拆卸防虫纱网 注意 禁止在拆下纱网的情况下打开换气扇 IN OUT 进风 出风 此按键可以调整扇叶旋转方向 风扇会逐渐减速并暂停两秒后改变 旋转方向并恢复转速 控制按键 使用方法请见 3 1 1 的控制说明 ARROW 使用 大扇叶 或者 小扇叶 按键进行风扇转速调整 当风扇转速达到最高速 或最低速时 将会听到两声快速的 哔 声作为提示音 吊扇模式 当风扇电机运行时 关闭排气扇盖子 进入吊扇模式 风扇将继续运转进行内 循环 注意 车辆行驶时全开或者全闭 3 0 操作指南 3 1 手动打开换气扇 适用于 T1000 T2000 3 1 1 手动打开换气扇控制按键 适用于 T1000 T2000 1 2 3 1 2 3 ...

Page 9: ...止在拆下纱网的情况下打开换气扇 控制按键 使用方法请见 3 2 1 的控制说明 红外传感器 只有电动打开的型号 雨水传感器 只有电动打开的型号 如果室外雨水感应装置检测到有雨水 它会关闭风 扇并盖上盖子 1 2 3 温度传感器 只有电动打开的型号 该功能会根据设定的温度自行调节风扇转速 吊扇模式 当风扇电机运行时 关闭排气扇盖子 进入吊扇模式 风扇将继续运转进行 内循环 注意 车辆行驶时全开或者全闭 天窗模式 在 AUTO 模式下 按控制按键的关闭键 进入天窗模式 排气扇的扇叶停止 转动 排气扇盖子保持打开状态 再按控制按键的 ATUO 键或者按两下遥控器 AUTO 键 退出天窗模式 回复到 AUTO 模式 也可按关闭键关闭排风扇 3 2 自动打开换气扇 适用于 T3000 T5000 ...

Page 10: ...温度开启和关闭风扇 按下此按键一 次 不超过 3 秒 进入自动模式 三声短促的 哔 声确定风扇已经调整到了自动模式 如果要退出自动模式 按下 AUTO 键 恒温系统的出厂设定温度为 26 度 面板上的绿 色 LED 灯亮起代表目前处于自动模式 按下此按键风扇开启并进入自动模式后 风扇 会自动按照设定的温度进行运转 风扇转速会根据车内的温度进行自动调节 当车内 的温度上升时 风扇会自动加速 雨水感应器 按下此按键将关闭雨水感应器 这将关闭雨水感应探头 红色 LED 灯亮 起 代表雨水感应探头被关闭 请务必谨慎使用此按键 关闭雨水感应功能有可能会 使雨水流入到车内 当雨水感应器感应到雨时 将会自动关闭风扇和外盖 同时 红 色 LED 灯闪烁 提示雨水感应器已经关闭了风扇 再次按下按键可以重新设定风扇并 关闭闪烁的红色 LED 灯 备注 请注意 当风扇外盖是通过手动旋转旋钮打开时 雨 水感应器将...

Page 11: ...FAN AUTO MODE 自动模式 按 键进入自动模式 THERMOSTAT SET TEMPERATURE 恒温温度设定 开启风扇 关闭风扇 自动模式下按 键将增高设定温度 自动模式下按 键将降低设定温度 自动模式下可以自动打开或关闭风扇外盖 风扇电机直接根据设定 温度进行运转 当车内的温度达到设定温度时 风扇外盖将自动关 闭 风扇电机停止运转 在自动模式下按 键将关闭自动模式 当风扇在手动模式下运转时 按 键将关闭外盖并进入吊扇模 式 备注 键无法在自动模式下使用 如果风扇脱离 12V 房车电源或 没有电源供给 请使用旋钮手动的打开或关闭风扇外盖 备注 恒温设置的温度设定范畴为 0度 37度 如果要切换将温度显示 由摄氏度变成华氏度 需要按下 键 3 3 遥控器操作说明 ...

Page 12: ...SSION SIGNAL 传输信号 按 键增加风扇转速 按 键降低风扇转速 风扇一共有 10 档速度可调 当 在遥控器屏幕上闪烁时 代表遥控器指令正在传输给风扇 风扇会发出 哔 的一声代表风扇已经接收到了遥控器的指令 LIGHT 灯泡 遮阳灯板照明 可以远程按 键控制遮阳灯板照明开 关 注 遮阳灯板为单 独产品 请根据需求购买 PLASMA 等离子 空气净化 按 开启空气进化功能 进风模式时可以进化部分空气 吊扇 模式时使用效果更佳 BRIGHTNESS ADJUSTMENT 亮度调节 遮阳灯板灯光调节 按 增加亮度 按 减少亮度 ...

Page 13: ...次启 动 该过程可以无限自动循环 持续排出有害气体 安全卫士启动后 只要有任意的人 为操作 安全卫士将人为主人已经知晓危险并排除了隐患 安全卫士功能将自动关闭恢 复正常运行 T5000 含此功能 T3000 可选装 备注 气体探头可以根据需求安装在任意需要的地方 探测范围可以根据需求调整 标 准配置为 500mm 2500mm 的延长导线 本功能不能取代专业的气体报警系统 远程控制 系统配置 485 通讯接口 通过通讯协议可与车载操作系统连接 实现集中 控制 T3000 T5000 含此功能 3 4 其他特殊功能说明 网络通讯 局域网链接功能 T5000 含此功能 空气净化 可选装 遮阳灯板 适用于 T1000 T2000 T3000 T5000 及所有开口相同的其他品牌产品 欢迎选用我们的配套产品 ...

Page 14: ...S T3000 T5000 3 0 OPERATING GUIDE 3 2 1 KEYPAD CONTROLS OPERATING GUIDE FOR AUTOMATIC OPENING MODELS APPLY TO MODELS T3000 T5000 3 1 MANUAL OPENING MODELS APPLY TO MODELS T1000 T2000 3 3 REMOTE CONTROL OPERATING GUIDE 3 4 OTHER SPECIAL FUNCTIONS 15 20 15 21 20 22 20 23 25 TABLE OF CONTENT NOTE Refer to Installation Instructions and Operation Guides regarding the model you have purchased READ AND S...

Page 15: ...LS Roof opening size 360mm X 360mm Roof thickness 48 134 mm Power supply 12 Volt DC Disconnect vehicle power before connecting 12 volts DC power to the fan 1 A 360mm X 360mm roof opening is required if you are replacing another fan already installed remove the old existing roof vent and sealant Figure 1 DANGER 1 360mm 3 6 0 m m ...

Page 16: ...e screw holes Figure 2 3 Connect the vehicle s 12 Volt power to the two wires on the fan Figure 3 Connecting to non 12 volt DC power or electrode connection error may damage the fan injury to persons or cause property loss This situation will invalid the warranty The white wire with a tag showing must be connected to the vehicle 12 volt positive supply 2 3 DANGER ...

Page 17: ... centering the fan in the opening Make sure the power wires slide to the interior Using the M4 X 25 screws provided screw the flange to the roof at each raised ring dimple location along the flange Screw into the dimple to pierce the flange making sure not to overtighten the screws to avoid cracking the flange Figure 4 4 ...

Page 18: ...er completed the roof top portion of the installation re apply 12 volt vehicle power The fan will emit a beeping sound to indicate the power is properly connected If the fan does not beep when the power is connected check the power again and whether the wires be correctly connected If the fan fails to operate please contact your dealer 5 ...

Page 19: ...interior Garnish Trim Ring can be trimmed according to your RV roof thickness or decoration requirement Figure 6 7 Fasten the Garnish Ring by using the four painted flat head screws provided and cover the screws with cover cap Figure 7 6 7 ...

Page 20: ...the opposite directions KEYPAD CONTROLS Please refer to section 3 3 1 Keypad Controls Operating Guide FAN SPEED Buttons to adjust fan speed Press the button with big fan icon to increase the fan speed press the button with small fan icon to decrease the fan speed When the fan speed reaches either the maximum or minimum speed the fan will respond with 2 quick beeping sounds to indicate this CEILING...

Page 21: ...ll turn off the fan and close the lid 1 2 3 TEMPERATURE SENSOR Automatic Models only The fan speed can be adjusted automatically according to the thermostat setting CEILING FAN MODE When the fan motor is running close the Vent Lid to enter Ceiling Fan Mode The fan motor will continue to run and circulate air within the RV cabin DANGER The fan is designed to be fully opened or fully closed when the...

Page 22: ...an enter the Auto Mode three quick beeps will confirm the fan has entered Auto Mode Press the AUTO button again can exit Auto Mode Initial factory set of the thermostat is 26 C The green LED will light to indicate the fan is in Auto Mode When the fan is in Auto Mode the fan will run automatically based on the temperature set The fan speed will automatically adjust based on the cabin temperature As...

Page 23: ...o the thermostat set temperature When the cabin temperature reaches the set temperature the fan lid will close and the fan motor will shut off Press button while in Auto Mode will shut off Auto Mode AIR EXHAUST INTAKE Press button to reverse the fan from exhaust or intake VENT LID POSITION Press button to open or close the vent lid When the fan is running in Manual Mode press button will close the...

Page 24: ...rification Press button to active Air purification function This function can purify the air when the fan is under intake mode it will be more effective if the fan be turn into Ceiling Fan mode BRIGHTNESS ADJUSTMENT Lighting system brightness adjustment Press button to increase the brightness Press button to decrease the brightness NOTE When the fan speed reaches either the maximum or minimum spee...

Page 25: ... any manually operation which can be identified that the RV owner already known the danger and eliminated the hidden danger then the air guard function will automatically shut down and resume to normal operation Standard function for T5000 Model optional for T3000 Model NOTE The gas sensor can be installed in any place according to the demand and the detection range also can be adjusted The standa...

Page 26: ...s Remote control manual control Sliding sunshade The window knob should not be higher than the interior to ensure the normal use of shading function Suitable for all 360 360 opening ceiling fans no te OTHER PRODUCTS FROM RV GUARDIAN ...

Page 27: ...27 Make A Difference 卓 尔 不 凡 EN ...

Page 28: ...深圳 有限公司 保留随时修改价格 材料 规格和型号的权利 或停止任何产品型号的生产 恕不另行通知 All rights reserved ARANA TECH Shenzhen Co Ltd reserves the right to modify at any time without notice prices materials specifications and models or to cease production of any model RV CEILING FANS 0920 V001 ...