25
Make A Difference 卓 / 尔 / 不 / 凡
EN
AIR GUARD:
Chemical sensors can detect dangerous gases. When the
concentration of dangerous gas exceeds the set range, and the fan has 12 volt
power supply, the fan will be unconditional turn ON to the maximum speed and
exhaust for 5 minutes to reduce the concentration of dangerous gas inside. After
5 minutes, the fan will switch to the startup default pattern. If the concentration
of dangerous gas does not decrease or still exceeds the standard after 5 minutes,
the air guard function will start again, and the process can automatically cycle
infinitely to continuously discharge dangerous gas. Once the air guard function
be activated, it can only be terminated by any manually operation which can be
identified that, the RV owner already known the danger and eliminated the hidden
danger, then the air guard function will automatically shut down and resume to
normal operation. (Standard function for T5000 Model, optional for T3000 Model)
NOTE:
The gas sensor can be installed in any place according to the demand, and
the detection range also can be adjusted. The standard configuration is 500mm ~
2500mm extension conductor. This function cannot replace the professional gas
alarm system.
INTEGRATED CONTROL:
Equip with 485 port, connecting with vehicle operating
system through communication protocol to realize integrated control. (T3000/
T5000 Models)
3.4 Other Special Functions
NETWORK:
LAN connection (T5000 Model Only).
AIR PURIFICATION:
Optional function
SUNSHADE AND LIGHTING SYSTEM:
Apply for T1000/T2000/T3000/T5000 Models
and other brands with same roof opening size.